SET FREE SERIES
FSXN1E
FSXNH(E)
INSTALLATION AND OPERATION MANUAL
MANUAL DE INSTALACIÓN Y FUNCIONAMIENTO
INSTALLATIONS- UND BETRIEBSHANDBUCH
MANUEL D’INSTALLATION ET DE FONCTIONNEMENT
MANUALE D’INSTALLAZIONE E D’USO
MANUAL DE INSTALAÇÃO E DE FUNCIONAMENTO
INSTALLATIONS- OG BETJENINGSVEJLEDNING
INSTALLATIE- EN BEDIENINGSHANDLEIDING
INSTALLATION- OCH DRIFTHANDBOK
ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ ΚΑΙ ΛΕΙΤΟΥΡΓΙΑΣ
PMML0294A_rev.2_02-2014.indb 1 14/07/2014 12:27:46
Question and Answer IconNeed help?

Do you have a question about the Hitachi RAS-12FSXN1E and is the answer not in the manual?

Hitachi RAS-12FSXN1E Specifications

General IconGeneral
Cooling Capacity3.5 kW
Heating Capacity4.0 kW
Indoor Unit Dimensions (W x H x D)845 x 275 x 209 mm
Outdoor Unit Dimensions (W x H x D)780 x 540 x 269 mm
Energy Efficiency Class (Cooling)A
Energy Efficiency Class (Heating)A
Power Supply230V, 50Hz

Summary

1 GENERAL INFORMATION

1.3 SAFETY

Explains safety symbols (DANGER, CAUTION, NOTE) and their meanings for safe operation.

1.3.2 Additional information about safety

Provides crucial safety warnings regarding electrical hazards, refrigerant leaks, and product usage.

1.3.3 Pressure vessel and safety device

Details safety measures related to the high pressure vessel and switch in the refrigerant system.

5 REFRIGERANT CYCLE

6 TRANSPORT, LIFTING AND HANDLING OF THE UNITS

7 UNIT INSTALLATION

7.1 PRELIMINARY CONDITIONS FOR POSITIONING OF OUTDOOR UNIT

Details site selection criteria for outdoor unit placement, considering sunlight, ventilation, noise, and access.

7.2 INSTALLATION SPACE

Specifies required clearances around the outdoor unit for installation and maintenance.

7.3 INSTALLATION

Provides guidelines for unit installation clearances based on surrounding walls.

7.4 FOUNDATION AND ANCHORAGE OF OUTDOOR UNIT

Details requirements for outdoor unit foundations, including height, drainage, and strength.

8 PIPING WORK AND REFRIGERANT CHARGE

8.1 REFRIGERANT PIPE SELECTION

Provides guidance on selecting correct refrigerant pipe sizes based on system type and outdoor unit power.

8.1.1 Refrigerant pipe selection

Provides guidance on selecting correct refrigerant pipe sizes based on system type and outdoor unit power.

8.1.2 Copper pipes, sizes, connection and insulation

Details specifications for copper pipes, including sizes, connection types, and insulation requirements.

8.1.5 Precautions for the installation of the outdoor unit

Guidelines for safe outdoor unit installation, including unit arrangement and pipe routing.

Size of pipes (Ø mm)

Table detailing pipe diameters for various systems and unit combinations.

For heat pump systems (2 pipes)

Table detailing pipe diameters for outdoor units and branches in 2-pipe heat pump systems.

For heat recovery systems (3 pipes)

Table detailing pipe diameters for outdoor units and branches in 3-pipe heat recovery systems.

9 ADDITIONAL REFRIGERANT CHARGE

9.1 AIR-TIGHT TEST

Details the procedure for performing an air-tight test on the refrigerant system, including valve checks and pressure testing.

9.2 VACUUMING

Explains the process of vacuum pumping the refrigerant system to remove moisture and air.

9.3 ADDITIONAL REFRIGERANT CHARGE CALCULATION

Provides formulas and tables for calculating additional refrigerant charge based on pipe length, diameter, and unit type.

9.4 CHARGING WORK

Details the process and precautions for charging refrigerant into the system.

9.5 AUTOMATIC SIMPLE JUDGEMENT SYSTEM FOR REFRIGERANT AMOUNT

Describes the automatic system for judging refrigerant amount, including procedure and results.

Special attention regarding refrigerant gas leakage

Highlights safety precautions for refrigerant gas leakage, including critical concentrations and ventilation requirements.

9.5.1 Precautions in the event of refrigerant leaks

Emphasizes strict adherence to safety regulations and discusses maximum permitted concentrations of HFC gases.

Countermeasures in the event of refrigerant leaks

Details room characteristics and ventilation required to mitigate risks associated with refrigerant leaks.

9.5.2 Drainage pipes

Explains the need for condensation drainage and provides guidance on selecting locations and using drainage kits.

10 ELECTRICAL WIRING

10.1 GENERAL INFORMATION

Provides general safety precautions and warnings related to electrical wiring work and inspections.

10.2 GENERAL VERIFICATIONS

Outlines checks for electrical components, supply voltage, installation conditions, and earth connections.

10.3 CONNECTION OF THE POWER SUPPLY CIRCUITS

Details power source wiring methods for heat pump and heat recovery systems.

10.3.1 Cable sizes

Provides minimum wire sizes for power source and transmission cables based on model and power supply.

10.3.2 Main breaker switch

Specifies electrical data, recommended wiring, and breaker sizes for each outdoor unit.

10.4 ELECTRICAL WIRING FOR OUTDOOR UNIT

Instructions for connecting electrical wiring to the outdoor unit's terminal board and PCB.

10.4.1 Connection of indoor units

Provides guidance on connecting indoor units, communication cables, and ensuring proper distances and shielding.

11 TEST RUN

11.1 PRELIMINARY CHECKS

Lists essential checks before performing a test run, including refrigerant pipes, wiring, and safety precautions.

11.2 CARRY OUT THE TEST RUN

Provides step-by-step instructions for carrying out the test run for indoor and outdoor units.

11.5 TEST RUN CHECK LIST

A comprehensive checklist for verifying system operation and parameters during the test run.

12 ALARM CODES

Most common alarm codes

Lists common alarm codes, their categories, abnormality content, and possible causes for quick troubleshooting.

13 CONTROL AND SAFETY DEVICES

Compressor protection

Details the devices and combinations that protect the compressor from overpressure and cold starts.

14 BASIC TROUBLESHOOTING

CAUTION

Safety warning regarding leaks, smoke, or abnormal sounds, advising immediate unit shutdown.

Related product manuals