– 26 –
MAINTENANCE
Cleaning and maintenance must be carried out only by quali ed service personal. Before cleaning,
stop operation and switch off the power supply.
1. PRE-FILTER
Clean the pre- lter, as it removes dust inside the room. In case the pre- lter is full of dust, the air
ow will decrease and the cooling capacity will be reduced. Further, noise may occur. Be sure to
clean the lter following the procedure below.
CAUTION
1
Open the front panel and remove the pre- lter
Gently lift and remove the air cleansing and
purifying lter from the pre- lter frame.
2
Vacuum dust from the pre- lter and air purifying
lter using vacuum cleaner. If there is too much
dust, rinse under running tap water and gently
brush it with soft bristle brush. Allow lters to
dry in shade.
3
Re-insert the air purifying lter to the lter
frame. Set the lter with “FRONT” mark facing
front, and slot them into the original state.
After attaching the lters, push the front panel
at three arrow portions as shown in gure and
close it.
CAUTION
Do not wash with hot water at more than 40°C. The lter may shrink.
When washing it, shake off moisture completely and dry it in the shade; do not expose it directly
to the sun. The lter may shrink.
Do not use detergent on the air purifying lter as some detergent may deteriorate the lter electrostatic
performance.
PROCEDURE
NOTE:
Air purifying lter should be cleaned every month or sooner if noticeable loading occurs. When used
overtime, it may loose its deodorizing function. For maximum performance, it is recommended to
replace it every 3-6 months depending on application requirements.
!
!