CONSTRUCTION AND DIMENSIONAL DIAGRAM
MODEL RAS-18GH5
Note:
1. Servicing space of 100mm or more is required on the left and right sides of the indoor unit and also 50mm or
more space is required above the unit
2. Insulated pipes should be used for both the narrow and wide dia. pipes.
3. Piping length is within 15m
4. Height different of the piping between the indoor unit and the outdoor unit should be within 10m.
5. Power supply cord length is about 2m
6. Connecting cable 2.5mm dia. x 3 (AB Line), 1.6mm dia. x 2 (CD Line) is used for the connection.
1019
Top air suction grille
47
47
28
147
380
About
About
350
31 120.5
56 17.5
60 60
7070
158
263 317450
Drain outlet
Connecting cable
Power cord
Hole on the wall
for ø 65mm pipe
Drain cap
connection port
Narrow pipe
Wide pipe
Drain
Drain hose
View from back
(Pipe lead-out)
When piping is
drawn horizontally,
exchange the drain
hose for the drain cap
6.5
60
Front cover
47
295
Vertical deflector
P
Horizontal deflector
Discharge grille
1030
191
207
6.5
60
47