EasyManua.ls Logo

Hitachi RAS-E18CY(J) - Air Flow Adjustments; Left and Right Air Flow Adjustment; Downward Air Flow Adjustment

Hitachi RAS-E18CY(J)
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 12 –
AIR FLOW LOUVERS ADJUSTMENTS
1. Adjusting the left and right air  ow directions
Move the vertical air  ow louvers as illustrated,
to adjust the air  ow to  ow towards the left or
right directions.
2. Adjusting the downward air  ow direction.
During the “Dehumidifying” or “Cooling” operating
modes, the horizontal air  ow louvers are auto-
matically adjusted to suit the air  ow angles of
each operating mode. The air  ow louvers are
designed to direct air  ow in upward and down-
ward directions. Pressing the automatic air  ow
control button, these air  ow louvers can also be
adjusted to any air  ow angle of one’s choice.
Press the AUTOMATIC AIR FLOW DIRECTION
once will activate the horizontal air  ow louvers
to direct the air  ows upwards and downwards.
Press the control button again, the horizontal air
ow louvers will stop moving and remain  xed at
the position at the point when the control button
was pressed
During the “Dehumidifying” or “Cooling” operat-
ing modes, set the horizontal air  ow louvers to
move within the range as recommended in the
illustration
Adjusting the air  ow louvers will direct air  ows
to assist in reducing the room temperature and
to correct any temperature imbalance
During the “Cooling” operating mode, do not
adjust the horizontal air  ow louvers to swing
outside the range as indicated by arrows in the
illustration. Do not operate the horizontal air  ow
louvers in durations longer than it is necessary.
Condensate may form and drip along the hori-
zontal air  ow louvers.
After stopping the operations of the unit by
pressing control button, the horizontal air
ow louvers will move to park at a position that
covers up the air outlet vent.
While the automatic air  ow direction mode is in
operation, any physical adjustment to the hori-
zontal air  ow louvers will shift the swing range.
However, with no further physical adjustments,
the air  ow louvers will readjust automatically to
the original swing range setting. (Should the lou-
vers could not return to the original swing range
setting, stop the operation of the air conditioner
unit, remove the power supply plug and re-plug
it into the power mains socket and restart the air
conditioner unit. This will return the swing range
to its original setting)
(EN2) RAS-E18CY (J)-DD 0000167C.indd 12 6/30/10 9:22 AM