6. Other Indications
6.1 In Normal Condition
A/C
Turned ON
Central Control
MODE SPEED LOUV.
HEAT
MED
TEMP
Meeting Room
6.1.1 Central Control
“Central Control” is turned ON.
In case that the prohibiting operation by remote
control switch is set from the central controller,
operation, temperature setting, fan speed and
direction setting are not available from the remote
control switch.
A/C
LOUV.
Motion sensor is activated
LOUV. ADJ
MODE SPEED
HEAT
MED
TEMP
Meeting Room
Turned ON
6.1.2 Motion Sensor Control
“Motion sensor is activated” is turned ON during
the motion sensor control.
In this case, the operation is performed with
saving the capacity or stopped by the motion
sensor control.
6.1.3 Defrost
• Defrost Operation
"DFR" is turned ON during the defrosting.
The indoor fan is stopped though the indication is
not changed.
The louver is xed at the horizontal position.
However, the louver indication of LCD continues
to activate.
• Operation Stoppage during Defrosting Operation
The RUN indicator (Green) is turned OFF when
the operation is stopped during the defrosting.
However, the operation continues with “DFR”
indication, and the unit is stopped after the defrost
operation is nished.
A/C
LOUV. ADJ
DFR
Turned ON
MODE SPEED LOUV.
HEAT
MED
TEMP
Meeting Room
6.1.4 Operation Control
• Supplying Main Electrical Power
“HOT-ST” is turned ON at power-on.
In this case, the compressor is under preheating.
The operation may not be available for Max. 4
hours. Do not turn off the outdoor unit electrical
power during the high season for Cooling/Heating
operation.
• During Hot Start (Heating Operation Only)
“HOT-ST” is turned ON.
• Different Operation Mode
The operation mode set by the remote control
switch is different with the outdoor unit operation
mode.
(Except for the heat recovery system models.)
The indication of the actual operation mode
ashes.
The above display shows the case
that the cooling mode is set from the
remote control switch when the outdoor
unit operation mode is heating.
A/C
HEAT
LOUV.
LOUV. ADJ
COOL
MED
TEMPMODE SPEED
Flashing
Meeting Room
A/C
HOT-ST
LOUV. ADJ
Turned ON
MODE SPEED
HEAT
MED
TEMP
Meeting Room
A/C
LOUV.
HOT-ST
LOUV. ADJ
Turned ON
MODE SPEED
HEAT
MED
TEMP
Meeting Room