TC-12001
3-23
4-WAY CASSETTE
P5414964-rev.1
5
l
Do not step or put any material on the product.
l
Do not put any foreign material on the unit or inside the unit.
l
Do not turn OFF the main power source of the indoor unit during the season of heating and cooling.
The water can not be discharged forcedly so that overows from the drain pan.
As the result, the oor and the ceiling surface are smudged.
l
Hold the air lter and the air inlet grille by hand when attaching (removing).
If not, it may cause falling or injury.
l
Do not blow cold air to a person for a long time or overcool.
It may cause deterioration of physical condition and health impairment.
l
Do not install the indoor unit, outdoor unit, remote control switch and cable within approximately 3 meters
from strong electromagnetic wave radiators such as medical equipments.
l
Supply electrical power to the system to energize the oil heater for 12 hours before startup after a long
shutdown.
l
Make sure that the outdoor unit is not covered with snow or ice, before operation.
l
In some cases, the packaged air conditioner may not be operated normally under the following cases.
* In case that electrical power for the packaged air conditioner is supplied from the same power
transformer as the device*.
* In case that the power source wires for the device* and the packaged air conditioner are located close to
each other.
Device*: (Ex) Lift, container crane, rectier for electric railway, inverter power device, arc furnace,
electric furnace, large-sized induction motor and large-sized switch.
It consumes a large quantity of electrical power.
Regarding the cases mentioned above, surge voltage may be inducted in the power supply wiring for the
packaged air conditioner due to a rapid change in power consumption of the device and an activation of
switch.
Therefore, check the eld regulations and standards before performing electrical work in order to protect
the power supply for the packaged air conditioner.
l
Do not install the unit in the place where the air ow directly catches to animals or plants.
It could be the cause of adverse affect to animals or plants.
l
It is recommended that the room will be ventilated every 3 to 4 hours.
l
The heating capacity of the heat pump unit is decreased according to the outdoor air temperature.
Therefore, it is recommended that auxiliary heating equipment be used in the eld when the units is
installed in a low temperature region.
NOTICE
NOTE
CAUTION