E For false ceiling without opening
,IWKHUHLVQRRSHQLQJLQWKHH[LVWLQJIDOVHFHLOLQJSURYLGH
an opening in it before mounting the indoor unit. Cut out
the false ceiling. After hooking up the indoor unit, adjust
the position according to the procedure (a).
5
5
5
576~590
576~590
570
570
5
Dimension of opening
Indoor unit
Surface
RIÀDQJH
Dimension of opening
(OHFWULFDOER[
6 Tighten two nuts of each suspension bolt after the
DGMXVWPHQWLVFRPSOHWHG$SSO\/2&.7,*+7SDLQWWRWKH
suspension bolts and nuts in order to prevent them from
loosening. Adjust the indoor unit to the correct position,
using the checking scale.
N O T E
:KLOH DGMXVWLQJ WKHVSDFH EHWZHHQ WKHLQGRRU XQLW DQG WKH FHLOLQJ
VXUIDFH NHHS WKH LQGRRU XQLW OHYHO 2WKHUZLVH LW PD\ FDXVH D
PDOIXQFWLRQRIWKHÀRDWVZLWFK&KHFNWKHOHYHOQHVVRIWKHXQLWZLWK
DOHYHO
Level
Vinyl tube
Drain pipe
Corrugated board
Check the levelness at each corner (•) of the unit with a
level or by pouring water to the clear vinyl tube as shown in
WKH¿JXUH0DNHWKHFRUQHUDWWKHGUDLQSLSHVLGHWRPP
lower.
7 The upper surface of the unit is protected by corrugated
cardboard to prevent the unit from being damaged by
spatter, etc. When mounting the air panel (optional), check
WRHQVXUHWKDWZHOGLQJDURXQGWKHXQLWKDVEHHQ¿QLVKHG
before removing the corrugated cardboard.
,QVWDOODWLRQRIDLUSDQHO
Refer to
,QVWDOODWLRQRIRSWLRQDODLUSDQHO3$31$0.
1 Check the distance between the indoor unit and the false
ceiling. It is 16
+3
0
PPDVVKRZQLQWKH¿JXUH,IQRWDGMXVWWKH
distance by using the checking scale with maintaining the
levelness of the indoor unit.
2 &KHFNWKDWWKH¿[LQJVFUHZVIRUWKHSDQHODUHWLJKWHQHG
7LJKWHQWKH¿[LQJVFUHZVIRUWKHSDQHOXQWLOWRXFKLQJWKH
stopper to the suspension bracket.
N O T E
3D\DWWHQWLRQWRWKHGLVWDQFHEHWZHHQWKHLQGRRUXQLWDQGWKHIDOVH
FHLOLQJ ,ILW LV PP RU PRUH LW PD\FDXVH GHZ FRQGHQVDWLRQ E\
OHDNLQJDLUIURPWKHVHDOSDFNLQJ)LHOG6XSSOLHG
3 Check the indoor unit height from the false ceiling surface.
For air panel P-AP56WAM
3
Indoor unit
Ceiling surface
,QVWDOODWLRQRIUHPRWHFRQWUROVZLWFK
For details on installation of the remote control switch, refer to
Installation and Operation Manual of the product.