8.6.2.4  Space Heating 
If Controller type (LCDM)= “Unit” or “Unit+Room”.
•  Circuit 1   
•  Circuit 2 
 
Circuit 1 and Circuit 2
•  Water Calculation Mode   
•  Eco offset 
•  Working Limits 
•  Mixing Valve 
REF Access Description
Default 
Value
Range Steps Units Application
Notes
Circuit 1 and Circuit 2 S SC S80 M
C1WC Water Calculation Mode (Circuit 1) Gradient
Disabled 
Point 
Gradient 
Fix
1 - ○ ○ ○ ○ (*4)
C1ECO ECO offset water set (Circuit 1) 3 1~10 1 ºC ○ ○ ○ ○ (*1)
C2WC Water Calculation Mode (Circuit 2) Disabled
Disabled 
Point 
Gradient 
Fix
1 - ○ ○ ○ ○ -
C2ECO ECO offset water set (Circuit 2) 3 1~10 1 ºC ○ ○ ○ ○ (*2)
- Working Limits (Circuit 1 and 2) - - - - ○ ○ ○ ○ (*3)
- Mixing Valve (Circuit 2) - - - - ○ ○ ○ ○ (*2)
? NOTE
(*1): If Water calculation mode for circuit 1 heating (C1WC) is not set as “Disabled”.
(*2): If Water calculation mode for circuit 2 heating (C2WC) is not set as “Disabled”.
(*3): If Water calculation mode for circuit 1 heating (C1WC) or Water calculation mode for circuit 2 heating (C2WC) are not set as “Disabled”.
(*4): For YUTAKI S80 with DSW enabled for cooling, water calculation mode (Circuit 1) is set as “Fix”.