8.6.2.10  Optional Functions
Available if Controller type (LCDM)= “Unit” or “Unit + Room”.
•  System 
•  Space functions 
•  DHW (*1) 
? NOTE
(*1) Available if Status (DHWs)= “Enabled”.
 
System 
•  Hydraulic Sep. Status 
•  Energy Conguration 
•  Smart Function 
REF Access Description
Default 
Value
Range Steps Units Application
Notes
System S SC S80 M
hsb Hydraulic Sep. Status  Disabled Disabled / Enabled - - ○ ○ ○ ○ -
- Energy Conguration - - - - ○ ○ ○ ○ -
- Smart Function  - - - - ○ ○ ○ ○ -
Energy Conguration 
REF Access Description
Default 
Value
Range Steps Units Application
Notes
Energy Conguration S SC S80 M
PMConf Status Disabled Disabled / Enabled - - ○ ○ ○ ○ -
PM1 Power meter 1 Disabled
Disabled 
0.1 
1 
10 
100 
1000 
x10
1
pulse/
kWh
○ ○ ○ ○ (*1)
PM2 Power meter 2 Disabled
Disabled 
0.1 
1 
10 
100 
1000 
x10
1
pulse/
kWh
○ ○ ○ ○ (*1)
CAPCo. Capacity Conguration Disabled Disabled / Enabled - - ○ ○ ○ ○
? NOTE
(*1): If Status (PMConf) (“Status”)= “Enabled”
UNIT CONTROLLER
PMML0335A rev.1 - 04/2016
156