IOM 3.2 / HE OCT 2002
HITECSA
ISO 9002
EN29002
UNE66902
VERTICAL AIR COOLED AIR CONDITIONERS
& AIR TO AIR HEAT PUMPS
Self Contained (ACVZ, ACVBZ series)
& Split Systems (CCVZ/ECVZ, CCVBZ/ECVBZ series)
Installation, operation
and maintenance instructions
Self Contained ACVZ 351 401 501 701 721 751 801 1001 1002 1201 1402 1502 2002 2302 2402
Split, outdoor sectio CCVZ 351 401 501 701 721 751 801 1001 1002 1201 1402 1502 2002 2302 2402
Split, indoor section ECVZ 351 401 501 701 721 751 801 1001 1002 1201 1402 1502 2002 2302 2402
Nominal cooling capacity kW
10,0 11,5 14,9 18.7 19,5 22,2 23,4 30,0 29,8 36,0 37,4 44,4 60,0 67,0 72,0
Self Containe ACVBZ 351 401 501 701 721 751 801 1001 1201 1402 1502 1602 2002 2302 2402
Split, outdoor section CCVBZ 351 401 501 701 721 751 801 1001 1201 1402 1502 1602 2002 2302 2402
Split, indoor sectio ECVBZ 351 401 501 701 721 751 801 1001 1201 1402 1502 1602 2002 2302 2402
Nominal cooling capacity kW
9,8 11,5 14,7 18.6 19,4 22,1 23,2 29,7 35,0 37,2 44,2 46,4 59,4 66,0 70,0
Nominal heating capacity kW
10,4 12,7 15,6 19.6 20,6 23,5 24,4 31,7 37,0 39,2 46,6 48,8 63,4 70,0 74,0
COOLING MODELS
HEAT PUMP MODELS
Question and Answer IconNeed help?

Do you have a question about the Hitecsa ACVBZ Series and is the answer not in the manual?

Summary

GENERAL

SAFETY PRECAUTIONS

Essential safety guidelines and precautions for installation and maintenance personnel.

INSTALLATION LOCATION

Criteria for selecting an appropriate and safe location for unit installation.

AIR DUCTS

ELECTRICAL CONNECTIONS

Procedures and precautions for making secure and correct electrical connections.

RIGGING

SPLIT SYSTEMS VERSION

REFRIGERANT LINES CONNECTIONS AND REFRIGERANT CHARGE

Guidelines for connecting refrigerant lines and calculating refrigerant charge.

REFRIGERANT LINES SELECTION

Factors to consider when selecting appropriate refrigerant line diameters.

LINE DIAMETER

START UP

PRELIMINARY CHECK UP

Essential checks to perform before initiating the unit's start-up sequence.

UNIT START UP

Step-by-step process for safely starting the air conditioning unit.

DEFROST (Heat Pump Systems)

MAINTENANCE

REMOTE CONTROL OPERATION

START-UP CHECK LIST

Hitecsa ACVBZ Series Specifications