is typed for setting of year, it will be automatically changed to 2000, the smallest number
allowed. Also, bigger number than 2037 will also be changed to 2037.
13) IP ADDRESS
To enable network communication, there should be network devices physically connected to
each other, which have the same address that can be mutually recognized. Here, users can input
IP address, subnet mask, and gateway address required to distinguish mutually recognizable
address.
IP ADDRESS Setting Range
- IP address system of HEV-1000 complies with IPv4.
- The first BYTE can be set to any number from 1 to 223, except for 127 which is reserved for
loopback.
- for other BYTES, you can select any numbers from 0 to 255.
14) FTP SETTING
HEV-1000 provides a function to transmit event recordings and log files thereof to the remote
FTP server. To use this function, set the Host address, ID, and PW to access the remote FTP server
here in this menu.