3. LAK2 SeriesUL:
3.1 LAK2 can combine uniaxial or bi-axial linear actuators. For the sake of safety, two
actuators can't be operated simultaneously. Don't press the key and “▽”
key at the same time.
3.2 The output power of a controller is Max.144VA.
3.3 The input power is 100~240VAC.
3.4 Over current A:2.5A, B:3A, C:4A, D:5A, E:6A
3.5 Recommended installation method
4. LAK2B Series
4.1 LAK2B can combine uniaxial or bi-axial linear actuators.
4.2 The output power of a LAK2B controller is 144VA (The output voltage is 24VDC.).
4.3 1.3Ah or 2.9Ah lead acid batteries can be selected, built-in auto charge circuit
without an external charger.
4.4 Fuse specication2A/20mm(220/230VAC)
3A/20mm(100/110VAC)
10A/20mm(Battery).
4.5 Note: Please charge battery for at least 8 hours before initial use.
5. LAK2B Series (UL):
5.1 LAK2B can combine uniaxial linear actuators.
5.2 The output power of a LAK2B controller is 72.5VA (The output voltage is 24VDC).
5.3 1.3Ah or 2.9Ah lead acid batteries can be selected, built-in auto charge circuit
without an external charger.
2. LAK2 Series:
2.1 LAK2 can combine uniaxial or bi-axial linear actuators. For the sake of safety, two
actuators can't be operated simultaneously. Don't press the key and “▽”
key at the same time.
2.2 The output power of a controller is 108VA (The output voltage is 24VDC.).
2.3 LAK2 can be driven by DC (12VDC / 24VDC), which the output power depends on
the maximum power of power supply.
2.4 Fuse specication2A/20mm(220/230VAC)
3A/20mm(100/110VAC)
15A/20mm(12VAC).