TIPO MODELO DE ARREFECIMENTO
FICHA TECNICA
ALIMENTAÇÃO .......................................................................................... 230 V~50 Hz
ARREFECIMENTO
POTÊNCIA ................................................................................................... 2,75 kW
POTÊNCIA CONSUMIDA ........................................................................... 1,05 kW
CORRENTE CONSUMIDA ............................................................................... 4,7 A
COEFICIENTE DE EFICIÊNCIA ENERGÉTICA .................................................. 2,62
CORRENTE MÁX.
Arrefecimento .................................................................................................. 5,8 A
PRESSÃO MÁXIMA
ASPIRAÇÃO .............................................................................................. 1.160 kPa
COMPRESSÃO ......................................................................................... 4.120 kPa
REFRIGERANTE ........................................................................................ R410A 590 g
DIMENSÕES E PESO (LÍQUIDO)
UNIDADE INTERNA
ALTURA/COMPRIMENTO/PROFUNDIDADE ........................ 257/808/187 mm
PESO ..............................................................................................8,0 kg (NET)
UNIDADE EXTERNA
ALTURA/COMPRIMENTO/PROFUNDIDADE ........................ 535/695/250 mm
PESO ...............................................................................................30 kg (NET)
MODELO
FICHA TECNICA
ALIMENTAÇÃO .......................................................................................... 230 V~50 Hz
ARREFECIMENTO
POTÊNCIA ..................................................................................................... 3,4 kW
POTÊNCIA CONSUMIDA ........................................................................... 1,33 kW
CORRENTE CONSUMIDA ............................................................................... 6,2 A
COEFICIENTE DE EFICIÊNCIA ENERGÉTICA .................................................. 2,56
CORRENTE MÁX.
Arrefecimento ................................................................................................... 7,3 A
PRESSÃO MÁXIMA
ASPIRAÇÃO .............................................................................................. 1.160 kPa
COMPRESSÃO ......................................................................................... 4.120 kPa
REFRIGERANTE ........................................................................................ R410A 720 g
DIMENSÕES E PESO (LÍQUIDO)
UNIDADE INTERNA
ALTURA/COMPRIMENTO/PROFUNDIDADE ........................ 257/808/187 mm
PESO ..............................................................................................8,0 kg (NET)
UNIDADE EXTERNA
ALTURA/COMPRIMENTO/PROFUNDIDADE ........................ 535/695/250 mm
PESO ...............................................................................................32 kg (NET)
UNIDADE EXTERNA
HSW-9FA
HOW-9FA
UNIDADE INTERNA
UNIDADE EXTERNA
HSW-12FA
HOW-12FA
MODELO
TIPO MODELO DE ARREFECIMENTO
UNIDADE INTERNA
OPERATING MANUAL
BEDIENUNGSANLEITUNG
MODE D’EMPLOI
MANUAL DE FUNCIONAMIENTO
MANUALE DI ISTRUZIONI
ΕΓΧΕΙΡΙ∆ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ
MANUAL DE INSTRUÇÕES
KEEP THIS OPERATION MANUAL
FOR FUTURE REFERENCE
P/N9312175055-01
Indoor Unit
HSW-9FA
HSW-12FA
Outdoor Unit
HOW-9FA
HOW-12FA
COOLING MODEL
ROOM AIR CONDITIONER
WALL MOUNTED TYPE
EC DECLARATION OF CONFORMITY
CE-KONFORMITÄTSERKLÄRUNG
DECLARATION DE CONFORMITE-CE
CE DECLARACIÓN DE CONFORMIDAD
DICHIARAZIONE DI CONFORMITÀ CE
∆ΗΛΩΣΗ ΕΓΚΡΙΣΗΣ ΚΑΤΑΛΛΗΛΟΤΗΤΑΣ
CE VERKLARING VAN OVEREENSTEMMING
EG-FÖRSÄKRAN OM ÖVERENSSTÄMMELSE
DECLARAÇÃO DE CONFORMIDADE DA
COMUNIDADE EUROPEIA (CE)
HIYASU, S.A.
Calle Brasil, 52-54 08028 Barcelona
declares under its sole responsibility that the air conditioning models
erklärt hiermit, daß die nachfolgend bezeichneten Raumklimageräte
déclare sous sa seule responsabilité que les modèles de climatiseur ci-dessous
declara bajo su exclusiva responsabilidad que los modelos de acondicionadores de aire
dichiara sotto la sua unica responsabilità che i condizionatori d’aria modelli
δηλώνει, οτι µε δική τησ υπευθυντητα τα µοντέλα των κλιµατιστικών
verklaart onder eigen verantwoordelijkheid dat de airconditioning-modellen
intygar på eget ansvar att luftkonditioneringsmodellerna
declara sob sua responsabilidade que os modelos de ar condicionado
to which this declaration relates is in conformity with the following standards:
worauf sich diese Konformitätserklärung bezieht, folgenden Richtlinien entspricht:
auxquels la présente déclaration s’applique, sont conformes aux normes suivantes:
como esta declaración especifica, cumplen con las siguientes normas:
ai quali si riferisce la presente dichiarazione sono conformi ai seguenti standars:
εισ τα οποία η παρούσα δήλωση αναφέρεται, είναι προσαρµοσµένα σύµφωνα µε τα παρακάτω πρτυπα:
waarop deze verklaring van toepassing is, in conformiteit zijn met de volgende normen:
till vilka denna deklaration är relaterade, är i överensstämmelse med följande standarder:
indicados na declaração estão em conformidade com as normas seguintes:
By conformance with the standards, the referenced products follows the provisions of the directives listed
below:
In Übereinstimmung mit den Standards, erfüllen die obengenannten Produkte den Verordnungen der unten
aufgeführten EG-Richtlinien:
Par leur conformité aux normes précitées, les appareils de ce type répondent aux exigences des directives
suivantes:
De acuerdo con estas normas, los productos referenciados cumplen lo estipulado por las directivas listadas a
continuación:
Od altri documenti normativi conformi alle disposizioni delle direttive sotto elencate:
Τα αναφερµενα µοντέλα, σύµφωνα µε τουσ κανονισµούσ, ακολουθούν τισ απαιτήσεισ ασφαλείασ των κάτωθι
άρθρων:
Overeenkomstig de normen, voldoen de betreffende produkten aan de bepalingen van de hieronder vermelde
richtlijnen:
Genom överensstämmelse med dessa standarder, uppfyller de berörda produkterna föreskrifterna i de
direktiv som anges här nedan:
Os seguintes produtos referenciados na lista abaixo, estão em conformidade com as normas:
Place of Issue : Spain Title of Authority : Administrator
Date of Issue : 24. JANUARY 2003 Declaration Reference : HIYASU, S. A.
Calle Brasil, 52-54
08028 Barcelona
a. EN 60 335-1
b. EN 60 335-2-40
c. EN 55 014-1
d. EN 55 014-2
e. EN 61 000-3-2
f. EN 60 335-2-80
HSW-9FA / HOW-9FA HSW-12FA / HOW-12FA
a. EC Council Directive 73/23/EEC b. EC Council Directive 89/336/EEC
Authorized by : Signature:
Jordi Santacana Tort
English
Deutsch
Français
Español
Italiano
EλληvIkά
Português
9312175055-01-cover.pm6.5 2003.4.21, 2:32 PM1
www.enindel.com

Other manuals for Hiyasu HSW-12FA

Questions and Answers

Summary

Safety Precautions

Danger Warnings

Critical safety warnings about potential personal injury from unit operation and handling.

Cautionary Advice

Important precautions for safe use, including avoiding prolonged exposure and proper handling.

Features and Functions

Automatic Operation

Unit starts automatic operation in Cooling or Dry mode based on thermostat and room temp.

Sleep Timer

Thermostat setting gradually raises during Cooling mode; unit turns off at set time.

Wireless Remote Control Unit

Convenient control of air conditioner operation via remote unit.

Swing Operation

Air flow direction louvers swing automatically up and down for room coverage.

Removable Intake Grille

Indoor unit's intake grille is removable for easy cleaning and maintenance.

Mildew-Resistant Filter

Air filter treated to resist mildew growth for cleaner use and easier care.

Super Quiet Operation

Selects QUIET fan control for reduced airflow and quieter operation.

Air Cleaning Filter (Optional)

Optional filter uses electrostatic principle to clean air of fine particulate matter.

Name of Parts

Indoor Unit Components

Identifies components of the indoor unit, including control panel and filters.

Outdoor Unit Components

Identifies components of the outdoor unit, including intake/outlet ports and pipe unit.

Remote Control Unit Overview

Details buttons and functions of the remote control unit.

Remote Control Unit Display

Explains display elements like operating mode, timer status, and fan speed.

Test Run Button

Button used for installation testing; not for normal operation.

Preparation

Power Connection

Connect the power supply plug to an electrical outlet or turn on the circuit breaker.

Battery Installation

Instructions for opening the compartment, inserting batteries, and closing the lid.

Remote Control Usage

Guidelines for pointing the remote at the signal receiver and expected range.

Battery Safety Precautions

Warnings regarding swallowing batteries, leakage, disposal, and mixing battery types.

Operation

Selecting Mode Operation

Instructions on using START/STOP and MASTER CONTROL buttons to select modes.

Setting the Thermostat

How to adjust thermostat settings using SET TEMP. button for different modes.

Setting the Fan Speed

Instructions for adjusting fan speed using FAN CONTROL button (AUTO, HIGH, MED, LOW, QUIET).

Stopping Operation

Press the START/STOP button to turn off the unit; OPERATION indicator lamp goes out.

Mode Operation Details

Details on automatic mode switching based on room temperature and thermostat settings.

Cooling Mode

Instructions for using Cooling mode to cool the room.

Dry Mode

Instructions for using Dry mode for gentle cooling and dehumidifying.

Fan Mode

Instructions for using Fan mode to circulate air, especially with space heaters.

Timer Operation

Using the OFF Timer

Procedure to set the OFF TIMER for automatic unit shutdown.

Using the ON Timer

Procedure to set the ON TIMER for automatic unit startup.

Cancelling Timer

Press the CANCEL TIMER button to deactivate any set timer.

Changing Timer Settings

Instructions to modify existing ON or OFF timer settings.

Stopping Operation with Timer

How to manually stop the unit even when a timer is active.

Changing Operating Conditions with Timer

How to adjust mode, fan speed, or thermostat after setting a timer.

Sleep Timer Operation

Using the Sleep Timer

Sets the timer for gradual thermostat adjustment and automatic shutdown.

Changing Sleep Timer Settings

Instructions to modify the previously set SLEEP timer duration.

About the Sleep Timer Function

Explains how SLEEP timer automatically adjusts thermostat for comfort and energy saving.

Confirming Timer Time

How to verify the set time for OFF, ON, or SLEEP timers.

Adjusting Air Circulation Direction

Vertical Air Direction Adjustment

How to adjust vertical airflow direction using the remote control's AIR FLOW button.

Safety Warnings for Airflow Adjustment

Crucial safety advice for adjusting airflow direction, including dangers and cautions.

Right-Left Airflow Adjustment

How to manually adjust horizontal airflow direction using the louvers.

Swing Operation

Selecting Swing Operation

Procedure to activate automatic up and down swinging of air flow direction louvers.

Stopping Swing Operation

Procedure to deactivate SWING operation and return to previous setting.

About Swing Operation

Details on swing range relativity, automatic switching, and stopping conditions.

Manual Auto Operation

Using Main Unit Controls

Instructions for operating the unit using its main control panel when remote is lost.

Cleaning and Care

General Cleaning Precautions

Important safety notes before cleaning, including disconnecting power and handling parts.

Cleaning the Intake Grille

Step-by-step guide for removing, cleaning, and replacing the intake grille.

Cleaning the Air Filter

Instructions for removing, cleaning (vacuum or wash), and replacing air filters.

Using the Optional Air Cleaning Filter

Guidance on installing and using the optional air cleaning filter.

Troubleshooting

Warning on Malfunctions

Immediate action for malfunctions like burning smells: stop, disconnect, consult service.

Operation Delays

Reasons for delayed operation, such as compressor protection or power connection.

Normal Operating Sounds

Explanation of normal sounds like water flow, coolant flow, and thermal expansion.

Smell Explanations

Possible causes of smells, including room odors absorbed by the unit.

Mist or Steam Emission

Explanation of mist formation due to rapid cooling and condensation.

Weak or Stopped Airflow

Reasons for weak airflow, including low fan speeds in specific modes.

No Operation Checks

Checks for power supply issues, fuse/breaker trips, or active timers.

Poor Cooling Performance Checks

Checks for dirty filters, blocked ports, incorrect thermostat settings, or open windows.

Remote Control Setting Discrepancy

Checks for SUPER QUIET operation or battery issues with the remote.

Operating Tips

Auto Restart Feature

Unit automatically restarts in previous mode after power interruption.

Power Interruption Impact

How timer operation is affected by power failures and potential interference sources.

Temperature and Humidity Ranges

Specifies optimal outdoor and indoor temperature ranges for Cooling and Dry modes.

Usage Restrictions

Notes on avoiding operation outside specified ranges to prevent damage or freezing.

Specifications

Cooling Model Specifications

Technical data for cooling capacity, power input, current, and efficiency ratios.

Pressure and Refrigerant Data

Maximum suction/discharge pressure and refrigerant type/quantity.

Indoor Unit Dimensions and Weight

Physical dimensions (height/width/depth) and net weight of the indoor unit.

Outdoor Unit Dimensions and Weight

Physical dimensions (height/width/depth) and weight of the outdoor unit.

Hiyasu HSW-12FA Specifications

General IconGeneral
BrandHiyasu
ModelHSW-12FA
CategoryAir Conditioner
LanguageEnglish