Operation and Maintenance Manual with
Illustrated Parts List for GPU-600
3-Phase Solid State
Transformer-Rectifiers
Series 500082-6xx
28.5 Volts, 600 Amps
OM 2244
12/15/2014 Rev A

Questions and Answers

  • K
    katie31Aug 1, 2025
    How to troubleshoot a Hobart 6T28-600CL Transformer machine that will not start?
    • S
      Scott HodgesAug 1, 2025
      If your Hobart Transformer machine won't start, there are several potential causes: * The input power may be turned OFF at the remote disconnect switch. To solve this, turn the power ON at the remote disconnect switch. * There might be a blown fuse in the remote disconnect switch. Replace the blown fuse. If the fuse blows frequently, determine and fix the underlying cause. * There could be incorrect input power connections at the machine. Check the input power connections against the appropriate connection diagram. * The power input (frequency and voltage) might be incorrect. Ensure the voltage and frequency of the power input match the rating on the machine's nameplate. * A broken input cable could be the issue. Repair the cable as needed.
  • K
    Kimberly MolinaAug 9, 2025
    Why does the line contactor fail to close on my Hobart Transformer?
    • M
      Marissa BarrettAug 9, 2025
      If the line contactor fails to close on your Hobart Transformer, here are a few things to check: * The line contactor fuse F8 may be blown. Replace the fuse. If the fuse blows frequently, check for the cause. * There might be a mechanical obstruction on the contactor. Remove any obstruction. * The line contactor switch could be defective. Replace the line contactor switch. * The coil in the line contactor might be defective. Replace the contactor if the coil is open or shorted. * A cable could be broken at the line contactor. Repair the broken cable as necessary.
  • E
    Elizabeth HuffAug 18, 2025
    How to fix high output voltage on Hobart Transformer?
    • C
      Courtney CampbellAug 18, 2025
      If the output voltage of your Hobart Transformer is too high (above 32 Volts), consider these causes: * The voltage calibration might be off. Attempt calibration. If calibration isn’t possible, replace the PC control board. * The voltage sensing lead could be open. Repair or replace the voltage-sensing lead.
  • H
    Holly JonesAug 22, 2025
    What causes unstable voltage in a Hobart 6T28-600CL Transformer?
    • C
      conniebrownAug 22, 2025
      If you're experiencing unstable voltage with your Hobart Transformer, here are potential causes and solutions: * An open filter capacitor. Find and replace the defective capacitor. * One or more SCRs not firing properly. Adjust the balance control or replace the defective SCR heat sink assembly if an oscilloscope shows faulty SCR devices. Replace PC control boards if the oscilloscope shows no gate pulse and the PC control board inputs and controls are proper except for output.
  • J
    James ClarkAug 27, 2025
    What to do if operator gets a shock from Hobart Transformer?
    • C
      Christie ElliottAug 27, 2025
      If an operator receives a shock when touching the Hobart Transformer machine case, it's likely due to the case not being grounded. Ground the machine case to an earth-type ground if the utility ground is already connected. Connect the normal safety ground and recheck if the 'utility' ground had not been connected.
  • T
    Tanya ByrdNov 4, 2025
    What to do if Hobart Transformer delivers power but soon shuts down?
    • M
      Melvin SmithNov 4, 2025
      If your Hobart Transformer unit delivers power but soon shuts down due to thermal overload, electronic overload, or over-voltage circuit trips, consider these potential causes: * The power supply might be overloaded. Reduce the load, as overload can only be sustained for a short time. * The duty cycle may be too high. Avoid continuous operation at overload currents. * The ambient temperature could be too high. Operate at reduced loads when the temperature exceeds 104° F (40° C), or improve the cooling ambient. * Ventilation might be blocked. Ensure that air intake and exhaust openings are not obstructed. * The fan may not be operating. Check fuse F1 on the fan shroud. If the fuse is good, disconnect the fan motor leads and apply 115 VAC directly to the fan motor. Replace the fan...
  • P
    patricia32Nov 12, 2025
    Why won't the output contactor close on my Hobart 6T28-600CL?
    • D
      David SosaNov 12, 2025
      If the output contactor of your Hobart Transformer will not close, consider the following: * The output switch (S2) may be defective. With the unit off, place a jumper between terminals 2 and 4 on S2. Turn the unit on. If the output contactor closes, S2 is defective and should be replaced. * The input contactor auxiliary contacts (K1) may be defective. With the unit off, place a jumper between terminals NO 1 and COM 3 on the input contactor. Turn the unit on, and place S2 in the Close position. If the output contactor closes, K1 is defective and should be replaced. * The output voltage select switch (S103) may be defective (if applicable). With the unit off, place a jumper between terminals 4 and 5 on S103. Turn the unit on, and place S2 in the Close position. If the output contacto...

Summary

Safety Warnings and Cautions

Shock Prevention

Measures to prevent electrical shock hazards during operation.

Service and Maintenance Safety

Safety procedures for performing maintenance and servicing.

Chapter 1 Description;Operation

Chapter 2 Servicing; Troubleshooting

Section 1 Troubleshooting

General information and procedures for diagnosing and resolving equipment faults.

Section 2 Calibration and Test of PC Control Board

Steps for testing, calibrating, and identifying issues with the PC control board.

Chapter 3 Overhaul; Major Repair

Unscheduled Repair

General guidance for performing unscheduled repairs and factory service.

Component Removal and Replacement

Instructions for replacing common components like lights, fuses, and diodes.

SCR Diode Replacement

Specific procedures and tools required for replacing SCR diodes, including force measurement.