EasyManua.ls Logo

Hobby T 555 FS - Chapter 9: Gas; LPG Fitting Safety Rules

Hobby T 555 FS
161 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Gas
09-1
Chapter 9: Gas
9.1 General safety rules for the use of
LPG ttings
Checking the gas ttings
• Beforeinitialoperation,havetheLPGttingscheckedbyan
expert.
• Thegasttingsmustbecheckedevery2yearsbyanLPG
expert.Thismustbeconrmedonthecerticate(conform
withFormG607fromtheGermanAssociationofGasand
WaterExperts).
• Theregulatorandwastegaspipesmustalsobechecked.
• Werecommendthatyoureplacethesafetyregulatoratleast
every6years.
• Theconnectinghoseshouldalsobecheckedregularlyfor
damage.Replaceit immediately ifyound tears, porous
spotsorsimilardamage.
• Theoperatorisresponsibleforhavingcheckscarriedout.
Ifyoususpectthatgasisleaking,takethefollowingmea-
suresimmediately:
•Shutthestopvalveonthegasbottle.
•Ignitionsourcessuchasopenreorsmokingare
strictlyforbidden.
•Airtherooms.
•Clearthedangerzone.
•Informyoursurroundings(groundsman)and,ifneces-
sary,theredepartment.
Thegasttingsmayonlybetakenintooperationagain
aftertheyhavebeencheckedbyanexpert.
Built-in objects and changes
• Onlyanexpertmaybuildinobjectsandmakeanychanges
tothegasttings.
• Deviceswithdifferentconnectingscrewsmaynotbeope-
rated.
Storing objects
• Gasbottlesmustalwaysstandupright.
• Cupboardsforgasbottlesmustbesealedupfromtheliving
quarters.
• Cupboards for gasbottles must have a vent of at least
100cm
2
inordirectlyabovetheoor.

Table of Contents