Adres producenta/ Adresse des Herstellers/ Manufacturer’s Address/ Адрес производителя
GTV Poland Sp. z o.o. Sp. k., ul. Przejazdowa 21, 05-800 Pruszków
Update Rate 3/s Flashlight
Low Battery Indication Auto Power Off
5.2 Electrical specyfication
Continuity test
NCV
2. VOLTAGE DC/AC
Function Range Resolution Accuracy Max
DC
VOLTAGE
(V)
6V 0.001V
±(0.5%+5d)
600V
60V 0.01V
600V 0.1V
±(0.8%+5d)
(1000V) 1V
AC
VOLTAGE
(V)
6V 0.001V
±(1%+5d)
600V
60V 0.01V
600V 0.1V
±(1%+8d)
(750V) 1V
* * Frequency response at AC modes: 40Hz ~ 1kHz.
* * Note: To prevent burning, do not measure voltage over 600V!
3. Resistance
Function Range Resolution Accuracy Max
Resistance
600.0Ω 0.1Ω
±(1.3%+5d)
60MΩ
6.000kΩ
60.00kΩ 10Ω
±(1.0%+5d)600.0kΩ 100Ω
6.000MΩ 1kΩ
60.00MΩ 10kΩ ±(1.5%+5d)
4. AC/DC CURRENT
Function Range Resolution Accuracy Max
DCA
1A 1mA
±(1.0%+5d)
10A
10A 10mA
ACA
1A 1mA
±(1.2%+6d)
10A 10mA
5. CAPACITANCE
Function Range Resolution Accuracy Max