6. GENERATOR USE
The generator produces enough electric power to cause a serious shock
or electrocution if misused.
Be sure to ground the generator when the connected appliance is
grounded.
To ground the terminal of the generator,
use a copper wire with same or larger
diameter than the cord of the
connected appliance.
Use extension cord set with ground conductor when connecting an
appliance with ground conductor.
To identify the Ground pin in the plug, see RECEPTACLE page 52.
Connect a RCBO (Residual current circuit breaker with overload
protection) of 30 mA ground fault detection and cut-off of less than
0.4 seconds at more than 30 A of output current, if you are using two
or more appliance.
Follow the instructions provided by each RCBO manufacturer before
use.
Improper connections to a building’s electrical system can allow
current from the generator to backfeed into the utility lines.
Such backfeed may electrocute utility company workers or others who
contact the lines during a power outage, and the generator may
explode, burn, or cause fires when utility power is restored.
Consult the utility company or a qualified electrician prior to making
any power connections.
EARTH
MARK
GROUND TERMINAL
GENERATOR
RCBO
APPLIANCES
GENERATOR
RCBO
APPLIANCES
RCBO
Connecting with one RCBO Connecting with two RCBO
<6DQQMࡍ࡯ࠫ㧞㧜㧝㧞ᐕ㧣᦬㧟㧝ᣣޓἫᦐᣣޓඦᓟ㧞ᤨ㧟㧣ಽ

Table of Contents

Other manuals for Honda EU10i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honda EU10i and is the answer not in the manual?

Honda EU10i Specifications

General IconGeneral
ModelEU10i
TypeInverter
EngineHonda GXH50
Weight13 kg
Dimensions450 x 240 x 380 mm
Starting SystemRecoil
Run Time at 1/4 Load8.3 hours
Displacement49.4 cc
Voltage230V
Frequency50 Hz
Maximum AC Output1000 VA
Rated AC Output900W
Fuel Tank Capacity2.1 liters
Continuous Operating Time8.3 hrs @ 1/4 Load
Engine Type4-stroke, single-cylinder