TRANSPORTING/STORAGE
When transporting the generator, turn the engine switch and the fuel valve
OFF. Keep the generator level to prevent fuel spillage. Fuel vapor or spilled
fuel may ignite.
m Contact with a hot engine or exhaust system can cause
serious burns or fires. Let the engine cool before transporting or storing
the generator.
Take care not to drop or strike the generator when transporting. Do not place
heavy objects on the generator.
Before storing the unit for an extended period:
1. Be sure the storage area is free of excessive humidity and dust.
2. Service according to the table below:
STORAGE TIME
RECOMMENDED SERVICE PROCEDURE
TO PREVENT HARD STARTING
Less than 1 month
1 to 2 months
No preparation required
Fill with fresh gasoline and add gasoline
conditioner*.
2 months to 1 year
Fill with fresh gasoline and add gasoline
conditioner*.
Drain the carburetor float bowl (page 32).
Fill with fresh gasoline and add gasoline
conditioner*.
1 year or more
Drain the carburetor float bowl (page 32).
Remove the spark plug. Put a tablespoon of
engine oil into the cylinder. Turn the engine
slowly with the pull rope to distribute the oil.
Reinstall the spark plug.
Change the engine oil (page 24).
After removal from storage, drain the stored
gasoline into a suitable container, and fill
with fresh gasoline before starting.
* Use gasoline conditioners that are formulated to extend storage life.
Contact your authorized Honda generator dealer for conditioner
recommendations.