HE360 HUMIDIFIER
9 69-2631ES—13
Installing the Humidistat
1. Separate wallplate from humidistat.
Fig. 10.
Electrical Hazard
Can cause electrical shock or equipment damage. Disconnect power before beginning installation.
2. Mark the duct-tube hole. Hold the wallplate up to the desired location on the duct and make a mark inside
the duct tube hole.
Fig. 11.
3. Drill the duct-tube hole. Find your mark and drill a 1/2 in. hole in the duct. This is where the duct tube will
be inserted to capture air.
Fig. 12.
M34565A
Setting
Light
Next Auto
System
%
Replace BattReplace Batt
Inside
%
HUMIDITY BOOST
PULL HERE