Owners Manual
60 Hz Air-cooled Generators
8 kW to 22 kW
SAVE THIS MANUAL FOR FUTURE REFERENCE
Para español , visita: http://www.generac.com/service-support/product-support-lookup
Pour le français, visiter : http://www.generac.com/service-support/product-support-lookup
000918
Register your Honeywell product at:
WWW.HONEYWELLGENERATORS.COM
855-436-4636
(000209a)
WARNING
This product is not intended to be used in
a critical life support application. Failure to
adhere to this warning could result in
death or serious injury.

Table of Contents

Questions and Answers

  • M
    Michael StevensonAug 2, 2025
    What to do if my Honeywell 8 kW has no AC output?
    • L
      Lisa DawsonAug 2, 2025
      If there's no AC output from your Honeywell Inverter, first check if the main line circuit breaker is in the OFF (or OPEN) position. If so, reset the circuit breaker to ON (or CLOSED). The issue also might be a generator internal failure.
  • R
    Robert MorrisAug 8, 2025
    Why Honeywell 8 kW engine will not crank?
    • J
      Jennifer SimonAug 8, 2025
      If the engine of your Honeywell Inverter won't crank, possible causes include a blown fuse (correct the short circuit and replace the 7.5 Amp fuse in the generator control panel), loose, corroded, or defective battery cables (tighten, clean, or replace as necessary), a defective starter contact, a defective starter motor or a dead battery (charge or replace the battery).
  • C
    Craig KennedyAug 14, 2025
    What to do if Honeywell Inverter engine starts hard and runs rough?
    • C
      clarkdanielAug 14, 2025
      If your Honeywell Inverter engine starts hard and runs rough, it could be due to several reasons: * The air cleaner might be plugged or damaged (check/replace the air cleaner). * The spark plug(s) might be defective (clean, re-gap, or replace the plug(s)). * The fuel pressure might be incorrect (confirm fuel pressure to regulator is 10-12” water column (19-22mm mercury) for LP, and 3.5 - 7” water column (9-13mm mercury) for natural gas). * The fuel selector might be in the wrong position (turn fuel conversion valve to correct position).
  • B
    Brittany LeachAug 20, 2025
    What to do if Honeywell 8 kW Inverter engine cranks but will not start?
    • J
      jonathan89Aug 20, 2025
      If the Honeywell Inverter engine cranks but doesn't start, it could be due to: * being out of fuel (replenish fuel and turn on the fuel valve), * a defective fuel solenoid, * an open Wire 14 from the engine control board, * defective spark plugs (clean, re-gap, or replace the plugs), * or valve lash out of adjustment (reset valve lash).
  • T
    Tracy TownsendAug 27, 2025
    Why Honeywell Inverter unit consumes large amounts of oil?
    • C
      Charles RodriguezAug 27, 2025
      If your Honeywell Inverter unit is consuming large amounts of oil, possible causes include: the engine being overfilled with oil (adjust oil to the proper level), a defective engine breather, using the improper type or viscosity of oil (see “Engine Oil Recommendations”), or a damaged gasket, seal, or hose (check for oil leaks).

Summary

Safety Rules and General Information

General Safety Rules

Essential safety rules and definitions of hazard alerts (DANGER, WARNING, CAUTION) for safe operation.

General Hazards

Specific hazards related to general operation, moving parts, hot surfaces, and equipment damage.

Exhaust Hazards

Risks associated with generator exhaust gases, such as carbon monoxide asphyxiation.

Electrical Hazards

Risks of electrocution from bare wires, incorrect connections, and water contact.

Fire Hazards

Precautions against fire due to improper placement, hot surfaces, and fuel handling.

Explosion Hazards

Risks of explosion from flammable fuel vapors and the need to keep away from sparks.

Operation

Control Panel Operation

Using the Auto/Off/Manual interface, menu displays, and navigation system.

Manual Transfer Operation

Procedures for manually transferring loads between utility and generator power.

Automatic Transfer Operation

Detailed sequence for automatic transfer, cranking, cold start, and shutdown.

Maintenance

Performing Scheduled Maintenance

Importance of scheduled maintenance for optimal performance and emission compliance.

Service Schedule

Table outlining required maintenance tasks based on time or operating hours.

Troubleshooting

System Diagnosis

A table listing common problems, their causes, and suggested solutions for diagnosis.

Quick Reference Guide

System Diagnosis

Quick guide to active alarms, LED indicators, problems, checks, and solutions for system issues.