INSTALLATION INSTRUCTIONS
69-1710EFS-1
C7189U Remote Indoor Sensor
(USE WITH VISIONPRO
®
THERMOSTATS)
APPLICATION
This indoor sensor is designed to sense temperature at a remote location and send this information to the VisionPRO
Thermostat. This sensor can be used as a stand alone sensor or as part of an averaging network. Once a remote
indoor temperature sensor is connected to the thermostat, the thermostat's sensor is no longer used. The thermostat's
installer setup should be modified to tell the thermostat that remote indoor temperature sensor(s) have been used. The
Inside temperature reading on the thermostat's display will be the remote sensor(s) temperature location(s).
Fig. 1. C7189U Remote Indoor Sensor
SPECIFICATIONS
Operating Ambient Temperature Range:
45 to 88°F (7.2 to 32°C).
Display Range:
0 to 99°F (-18 to 37°C).
Sensor Accuracy:
+/-1.5°F at 70°F (+/-.84 at 21°C)
Operating Relative Humidity:
5% to 95% non-condensing.
Finish:
White.
Resistance Characteristics:
Negative temperature coefficient (NTC). Resistance
decreases as the temperature increases.
Dimensions in inches (mm):
1 1/2 (38) wide x 2 1/4 (57) high x 3/4 (19) deep.
Distance:
Maximum distance between thermostat and sensor is
200 feet.
Must be installed by a trained,
experienced technician
Read these instructions carefully. Failure to follow
these instructions can damage the product or cause a
hazardous condition.
Check the specification in this booklet to verify that
this product is suitable for the application.
Always test for proper operation after installation
M24055
Question and Answer IconNeed help?

Do you have a question about the Honeywell C7189U and is the answer not in the manual?

Honeywell C7189U Specifications

General IconGeneral
Wi-Fi ConnectivityNo
Humidity ControlNo
Accuracy±1°F (±0.5°C)
Output TypeRelay
TypeSmart Thermostat
DisplayLCD
Power SupplyBattery
Temperature Range (F)40°F to 99°F
Temperature Range (C)4 to 37°C
Sensor TypeThermistor
Input TypeThermistor
MountingWall-mounted

Summary

Application

Specifications

Sensor Specifications

Covers ambient temperature range, display range, accuracy, and humidity limits.

Physical Characteristics

Includes sensor dimensions and maximum connection distance.

Installation Requirements

Installation

Installation Tips

Guidance on sensor placement for optimal performance and distance.

Electrical Hazard Caution

Warning about electrical shock during installation.

Remote Sensor Wallplate Installation

Steps for mounting the sensor's wallplate to the wall.

Wiring

Electrical Hazard Warning

Caution regarding electrical shock and equipment damage before wiring.

Wiring Steps

Instructions for connecting the sensor wires to the thermostat.

Multiple Sensor Wiring

Configuration for connecting multiple sensors in an averaging network.

Operation

Thermostat Integration

How the remote sensor affects the thermostat's internal sensor and display.

Checkout and Calibration

Checkout Procedure

Steps to verify sensor accuracy using a thermometer and resistance table.

Calibration Information

Note that the sensor is factory calibrated and cannot be recalibrated in the field.