INSTALLATION INSTRUCTIONS
69-1410-2
T8601D Chronotherm® IV Deluxe
Programmable Thermostats
APPLICATION
The T8601 Chronotherm® IV Deluxe Programmable
Thermostat provides electronic control of 24 Vac single-
stage heating and cooling systems. Refer to Table 1 for a
general description of the thermostat. All T8601
thermostats require a common wire to supply power.
MERCURY NOTICE
If this control is replacing a control that contains
mercury in a sealed tube, do not place your old
control in the trash.
Contact your local waste management authority
for instructions regarding recycling and the
proper disposal of the old thermostat.
INSTALLATION
When Installing this Product...
1. Read these instructions carefully. Failure to follow
the instructions can damage the product or cause
a hazardous condition.
2. Check the ratings given in the instructions and on
the product to make sure the product is suitable for
your application.
3. Installer must be a trained, experienced service
technician.
4. After completing installation, use these instructions
to check out the product operation.
Location
Install the thermostat about 5 ft (1.5m) above the floor in
an area with good air circulation at average temperature.
See Fig. 1.
Do not install the thermostat where it can be affected by:
drafts, or dead spots behind doors and in corners.
hot or cold air from ducts.
radiant heat from sun or appliances.
concealed pipes and chimneys.
unheated (uncooled) areas such as an outside wall
behind the thermostat.
Table 1. Description of T8601 Thermostats.
T8601 System Changeover System Selection Fan Selection Comments
D Heat-Cool Automatic Heat-Off-Cool-Auto On-Auto Use keyboard for system and fan selections

Questions and Answers:

Honeywell Chronotherm IV T8601D Specifications

General IconGeneral
TypeProgrammable Thermostat
Temperature Range40°F to 90°F (4°C to 32°C)
Power Source24V AC
CompatibilityConventional, Heat Pump
Schedule7-Day Programmable
Backup BatteryNo
Programmable Periods4 periods per day
Display TypeLCD
Terminal DesignationsR, C, W, Y, G
Voltage24VAC

Summary

INSTALLATION INSTRUCTIONS

Thermostat Application Overview

General description of the T8601D Chronotherm IV thermostat and its system requirements.

Mercury Thermostat Disposal

Instructions for proper disposal of thermostats containing mercury.

General Installation Instructions

Crucial steps and precautions before installing the thermostat product.

Optimal Thermostat Location

Guidelines for selecting the best place to install the thermostat for accurate readings.

Wallplate Installation

Thermostat Wiring Guide

Essential information and cautions for connecting thermostat wires according to codes.

Mounting the Thermostat Unit

Using Thermostat Keys

SETTINGS

System and Fan Configuration

How to set the thermostat's system (Heat/Cool/Auto) and fan (On/Auto) operation.

Temperature Scheduling

Details on setting default program temperatures and energy saving periods.

Installer Setup Options

Guide to customizing advanced thermostat settings for specific system configurations.

Setting Current Day and Time

Timer Settings Management

How to view or reset active timers on the thermostat display.

INSTALLER SELF-TEST

THERMOSTAT INFORMATION

System Checkout Procedures

Steps for checking specific features like the outdoor temperature sensor.

TROUBLESHOOTING GUIDE

Related product manuals