EasyManua.ls Logo

Honeywell F50F - Getting the Most From Your Electronic Air Cleaner; Run the electronic air cleaner as much as possible; Keep the cell(s) and prefilter(s) clean; Replace Activated Carbon Filters

Honeywell F50F
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
69-1150—2
7
F50F DUCT MOUNTED ELECTRONIC AIR CLEANER
P3
P4
E1/B2
E2/B4
J3
BLACK
W4 W2 W1 W3
AIRFLOW SWITCH BOARD
230VAC
ORANGE
GRAY
VIOLET
BLACK
L
N
BLACK
1 INTERLOCK SWITCH.
2 SHORTING BAR.
3 AIRFLOW SWITCH DISABLE JUMPER.
4 NEON LIGHT.
5 TRANSFORMER.
6 INPUT POWER. PROVIDE DISCONNECT
MEANS AND OVERLOAD PROTECTION AS REQUIRED.
M11977A
POWER
SUPPLY
2
4
BLACK
BLACK
3
6
1
5
J4
J5
J1
BLACK
RED
TEST
BUTTON
CONTACT
BOARD
RED IONIZER
BLACK COLLECTOR
Fig. 11. Internal schematic for CE compliant 230V, 2 cell F50F models.
Fig. 12. Internal schematic for CE compliant 230V, 1 cell F50F models.
P3
P4
J3
BLACK
W4 W2 W1 W3
AIRFLOW SWITCH BOARD
ORANGE
GRAY
VIOLET
1 INTERLOCK SWITCH.
2 SHORTING BAR.
3 AIRFLOW SWITCH DISABLE JUMPER.
4 BROWN WIRE TO TOP TERMINAL.
5 INPUT POWER. PROVIDE DISCONNECT
MEANS AND OVERLOAD PROTECTION AS REQUIRED.
6 NEON LIGHT.
M11978 A
2
6
TEST
BUTTON
CONTACT
BOARD
RED IONIZER
BLACK COLLECTOR
BLACK
BLUE
BROWN
BLACK
3
4
J4
J5
J1
230VAC
L
N
5
1