Heating equip- o Check Installer Setup, Function 1 (System Type), to make sure it is set to
merit is running match the installed heating/cooling equipment (see page 8).
in cool mode
Cannot change
system setting
to "Heat"
* Check Installer Setup, Function 1 (System Type), to make sure it is set to
match the installed heating equipment (see page 8).
Change Installer Setup, Function 12 (System Setting) to Manual or Auto
Chan eogeover(see page 8).
Cannot change
system setting
to "Cool"
"Heat On" is
net displayed
* Check Installer Setup, Function 1 (System Type), to make sure it is set to
match the installed cooling equipment (see page 8).
* Change Installer Setup, Function 12 (System Setting) to Manual or Auto
Chan eogeover(see page 8).
o
Change the System Setting to Heat, and set the temperature level above
the current room temperature.
"Cool On" is not * Change the System Setting to Cool, and set the temperature level below
displayed the current room temperature.
_=Coel On" or
"Heat On"
is flashing
o Compressor protection timeout is engaged. Wait 5 minutes for the
system to restart safely, without damage to the compressor.
'_ " _ " _ " ® . 6'{" H " |_. m " 4
Please contact your distributor to order replacement parts.
Batter,/holder ...................................................... Part Number 50007072-001
Cover plate assembly ........................................ Part Number 80002883-001
(Use to cover marks left by old thermostats,}
4
Temperature Ranges Electrical Ratings
, Heat: 40° to 90°F (4.5 ° to 32°C)
, Cool: 50 ° to 99°F (10 ° to 37°C) Terminal Voltage (50/60Hz) Running Current
Operating Ambient Temperature W (O/B) Heating 20-30 Vac
32 ° to 120°F (0° to 48.9°C)
(Powerpile) 750 mV DC
Shipping Temperature
, -20 ° to 120°F (-28.9 ° to 48.9°C) Y Cooling 20-30 Vac
G Fan 20-30 Vac
Operating Relative Humidity
, 5% to 90% (non-condensing)
0.02-1.0A
100mADC
0.02-1.0A
0.02-0.5A
Physical Dimensions
o 3-9/16" H x 5-13/16" W x 1-1/2" D
* 91 mmHx147mmWx38mmD