EasyManuals Logo

Honeywell LYNX Touch Step-By-Step Guide

Honeywell LYNX Touch
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Step-by-Step
Options for External Sounders on the LYNX Touch
The LYNX Touch panels have no Siren output, they are intended to use the 5800Wave Wireless Siren when additional
sounding is needed. If you want to add Hardwire Sirens you have the two options below. Lynx Touch Panels with
Automation can also use a Z-Wave Siren/Strobe as described on page 2.
1. If you desire a sounder in a location where you cannot get a wire from the LYNX Touch you have the option to use a
5800RL Wireless Relay Module following this setup:
2. If you can get a wire from the LYNX Touch to where you want the sounder you can use this setup: (An Altronix
RBSN-TTL sensitive relay and power supply are required)
Due to the 3mA current limit of the
LYNX Touch output trigger, the
Altronix TTL Sensitive relay must
be used. A jumper wire is required
from TRG+ to the POS+ terminal,
as well as a common ground.
In Device or Rule Programming,
program the Trigger with an Action
and Start and Stop event, such as
“Permanent On, Start on System
Operation-Any Burglar Alarm, Stop
on System Operation-Bell
Timeout
NOTE: The Trigger can be
programmed to start on System
Operation 'Any Burg' or 'Any Fire'.
System Operation 'Any Burg'
encompasses alarms on these zone
types:
Entry/Exit #1, Entry/Exit #2
Perimeter, Interior Follower, Interior Delay, Silent Burglary Alarm
Trouble Day/Alarm Night
24 Hr. Silent Alarm and 24 Hr. Audible Alarm
System Operation 'Any Fire' encompasses alarms only on Fire Without Verification zone type
- 1 -
Tech Support
Updated 4/22/15

Other manuals for Honeywell LYNX Touch

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell LYNX Touch and is the answer not in the manual?

Honeywell LYNX Touch Specifications

General IconGeneral
ZonesUp to 64 wireless zones
Voice ControlNo
Remote ControlYes, via mobile app
Keypad ZonesNo
PartitionsNo
Voice PromptsYes
Built-in Z-WaveYes
DisplayColor touchscreen
CommunicationCellular
Wireless Zones64
AutomationZ-Wave
Siren OutputBuilt-in
Wireless Frequency345 MHz
Supported Security DevicesDoor/window sensors, motion detectors
CompatibilityHoneywell 5800 series wireless devices