EasyManua.ls Logo

Honeywell MAXON VALUPAK-II 150 User Manual

Honeywell MAXON VALUPAK-II 150
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
TECHNICAL CATALOG
32-00188-01
VALUPAK®-II
Low Temperature Burners
High turndown
•Available in 4 sizes
Capacities 2 kW - 558 kW (HHV)
Stable and clean combustion
Suitable for UV scanner and flame rod
Low gas pressure requirements
Ease of installation and operation with low
maintenance requirements
All metal construction
Multi voltage and frequency blower motors
Better control on CO over the entire turndown of the
burner
Pilot connection availability
Easily Switch between Natural Gas and Propane
PRODUCT DESCRIPTION
The VALUPAK®-II is designed for process air heating
applications.
A motorized gas control valve controls the heat output of
the burner over the full operating range. The gas flows
through the nozzle and then along the inside of the burner
cone where combustion air is progressively and
tangentially mixed with the gas. This results in a short, very
stable flame and clean combustion.
Like many other Honeywell products, the standard
VALUPAK-II burner can be customized into a package
which could include a gear motor, burner controls,
automatic shut-off valves, flame sensors and/or pressure
switches.
Question and Answer IconNeed help?

Do you have a question about the Honeywell MAXON VALUPAK-II 150 and is the answer not in the manual?

Honeywell MAXON VALUPAK-II 150 Specifications

General IconGeneral
BrandHoneywell
ModelMAXON VALUPAK-II 150
CategoryBurner
LanguageEnglish

Summary

Product Description

Available VALUPAK-II Sizes

Dimensions - VALUPAK-II 60

Dimensions - VALUPAK-II 150, 300 & 600

Applications

Application Examples

Showcases practical uses and examples of the VALUPAK-II burner in various industrial settings.

Options

Specifications for 50 Hz Operation

Installation and Operating Instructions

Installation Instructions

Guidance for the correct installation of the VALUPAK-II burner system, prioritizing local codes.

Burner Mounting

Details on how to mount the burner, including cutting openings and supporting its weight.

Installation of Flame Scanner

Details on applying a flame scanner to the VALUPAK-II burner, with exceptions noted.

Flame Rod or UV Scanner Arrangement

Describes the arrangement for flame rods and UV scanners with spark ignitors.

Operating Instructions

Start-Up and Adjustment Instructions

Detailed steps for initial start-up, adjustment, and light-off by trained personnel.

First-Time Start-Up Procedure

Step-by-step guide for initiating the burner for the very first operation.

Related product manuals