EasyManua.ls Logo

Honeywell Prestige 2.0 THX9421 - Page 6

Honeywell Prestige 2.0 THX9421
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
THX9321 PRESTIGE
®
2.0 AND THX9421 PRESTIGE
®
IAQ WITH EIM
68-0311—07 6
Wireless Indoor
Sensor
C7189R1004 0 to 120 °F
(-17.8 to 48.9
°C)
For optimal
Battery Life:
35 to 114 °F
(1.7 to 45.6 °C)
5% to 90%
Non-Condensing
-20 to 120 °F
(-28.9 to 48.9 °C)
2-7/8 x 1-7/8 x 15/16
(74 x 48 x 24)
Arctic
White
Wired Outdoor
Sensor
(10K ohm
Negative
Temperature
Coefficient)
C7089U1006 -40 to 120 °F
(-40 to 48.9 °C)
5% to 95%
Non-Condensing
-40 to 130 °F
(-40 to 54.4 °C)
1-1/2 (38) - -
Wired Wall Mount
Indoor Sensor
(10K ohm
Negative
Temperature
Coefficient)
C7189U1005 45 to 88 °F
(7 to 32 °C)
5% to 95%
Non-Condensing
-20 to 120 °F
(-28.9 to 48.9 °C)
2-9/32 x 1-1/2 x 11/16
(58 x 38 x 18)
Premier
White
Wired Wall Mount
Indoor Sensor
(20K ohm
Negative
Temperature
Coefficient)
TR21 45 to 99 °F
(7 to 37 °C)
5% to 95%
Non-Condensing
-40 to 150 °F
(-40 to 65.5 °C)
4-9/16 x 3 x 7/8
(116 x 76.5 x 22)
White
Wired Wall Mount
Indoor Sensor
(10K ohm
Negative
Temperature
Coefficient)
TR21-A 45 to 99 °F
(7 to 37 °C)
5% to 95%
Non-Condensing
-40 to 150 °F
(-40 to 65.5 °C)
4-9/16 x 3 x 7/8
(116 x 76.5 x 22)
White
Wired Flush Mount
Indoor Sensor
(20K ohm
Negative
Temperature
Coefficient)
C7772A1004 45 to 99 °F
(7 to 37 °C)
5% to 95%
Non-Condensing
-40 to 150 °F
(-40 to 65.5 °C)
4-1/2 x 2-3/4 x 5/16
(114 x 70 x 8)
Brushed
Stainless
Steel
Wired Flush Mount
Indoor Sensor
(20K ohm
Negative
Temperature
Coefficient)
C7772A1012 45 to 99 °F
(7 to 37 °C)
5% to 95%
Non-Condensing
-40 to 150 °F
(-40 to 65.5 °C)
4-1/2 x 2-3/4 x 5/16
(114 x 70 x 8)
Brushed
Stainless
Steel
Discharge or
Return A
ir Sensor
(10K ohm
Negative
Temperature
Coefficient)
C7735A1000* 0 to 200 °F
(- 17.8 to 93.3
°C)
- - -20 to 120 °F
(-28.9 to 48.9 °C)
Probe:
3-3/4 x 1/4 (77 x 6.4)
Cap Diameter:
2-7/16 (62)
Gray
Discharge or
Return Air Sensor
(20K ohm
Negative
Temperature
Coefficient)
C7041 - - - - - - 4-3/16 x 2-5/16 x 1-
11/16
(107 x 59 x 43)
- -
Discharge or
Return Air Sensor
(20K ohm
Negative
Temperature
Coefficient)
C7770A1006 45 to 99 °F
(7 to 37 °C)
5% to 95%
Non-Condensing
-40 to 150 °F
(-40 to 65.5 °C)
Probe: 6 x 1/4
(152 x 6.4)
- -
Table 2. Thermostat Replacement Parts and Accessories. (Continued)
Product Part Number
Operating
Ambient
Temperature
Operating Relative
Humidity
Shipping
Temperature
Physical Dimensions in in.
(mm) Color(s)

Table of Contents

Related product manuals