Fig. 4—S8600A,B; S8610A,B with vent damper plug in an atmospheric burner heating system with a D80D vent
damper.
5
REMOVE PLUG ONLY IF USING VENT DAMPER.
M1185D
4
CONTROLS IN 24V CIRCUIT MUST NOT BE IN
GROUND LEG TO TRANSFORMER.
3 MAXIMUM CABLE LENGTH 3 FEET [0.9 METERS].
1 POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
2 ALTERNATE LIMIT CONTROLLER LOCATION.
DUAL VALVE COMBINATION
GAS CONTROL
1ST 2ND
OPERATOR OPERATOR
S8600A,B; S8610A,B
GND
MV MV/PV PV
(BURNER)
5 FOR MODULE WITH TH-W TERMINAL AND VENT
DAMPER PLUG, CONNECT THERMOSTAT TO TH-W.
LEAVE 24V OPEN. DO NOT REMOVE VENT DAMPER PLUG.
Q345, Q346,
Q348, Q362, Q381
PILOT BURNER/
IGNITER-SENSOR
2 ALTERNATE LIMIT CONTROLLER LOCATION.
3 MAXIMUM CABLE LENGTH 3 ft [0.9 m].
4 CONTROLS IN 24V CIRCUIT MUST NOT BE IN
GROUND LEG TO TRANSFORMER.
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
1ST 2ND
OPERATOR OPERATOR
2
DUAL VALVE COMBINATION
GAS CONTROL
COMBUSTION
AIR BLOWER
RELAY
S8600F,H,M; S8610F,H; S8660D; S8670D
Fig. 5—S8600F,H,M; S8610F,H; S8660D; S8670D connections in a heating system with power-assisted
combustion.