EasyManua.ls Logo

Honeywell T874 - Q672-Q674 Subbase Cross Reference

Honeywell T874
224 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
T874 MULTISTAGE THERMOSTATS AND Q674 SUBBASES
39 60-2485—8
Table 7. Q672-Q674 Subbase Cross Reference.
Model Number Description
Q674 Trade
Replacement
a
Remarks
Q672A System: HEAT-AUTO-COOL, Fan: AUTO-ON
A1005 Standard OEM Q674A1019
A1013 TRADELINE Q674A1019
A1021 RC-RH jumper Q674A1019 RC-RH jumper required.
A1039 RC-RH jumper; Chek Lite Q674A1019 RC-RH jumper required.
Q672B System: HEAT-OFF-COOL, Fan: AUTO-ON
B1004 Standard OEM Q674B1034
B1012 Isolated G terminal. Q674B1018
B1020 System: HEAT-OFF-RESET-COOL Q674B1034 Used system off as reset position.
B1038 TRADELINE Q674B1034
B1046 Heat pump circuit; used with T872R1008. Y594R1425 Wiring differences (old=new):
W1=Y1, W=W2.
B1053 RC-RH jumper Q674B1034 RC-RH jumper required.
B1061 Chek Lite Q674B1034
B1079 Auto fan operation in heat and cool. Q674B1075
B1087 Carrier no. HH93AZ078; RC-RH jumper. Q674B1075
B1095 Carrier no. HH93AZ084; RC-RH jumper. Q674B1034
B1103 Addison; heat pump circuit; used with
T872R1016.
Y594R1425 Wiring differences (old=new):
W=W2; W1-Y1 jumper required.
B1111 Carrier no. HH93AZ080; isolated G terminal. Q674B1018
B1129 Trane special circuit; used with T872T1004. None
B1137 RC-RH jumper; isolated G terminal. Q674B1018 RC-RH jumper required.
B1145 Fedders special Q674B1034 RC-RH jumper required.
B1152 Fedders special; auto fan operation in heat
and cool.
Q674B1075
B1160 Lennox; heat pump circuit; used with
T872R1024; includes compressor lockout in
EM. HT.
Y594R1243 Wiring differences (old=new):
V-VR=R, M=Y, Y=W2, F=G, R=O.
B1178 General Electric no. AY28X107; auto fan
operation in heat and cool.
Q674B1075
B1186 Trane; isolated G terminal; Filter LED. Q674B1018
B1194 General Electric no. AY28X124; auto fan
operation in heat and cool.
Q674B1075 Set T874 stage-1 anticipator for
combined load of heat relay and fan
relay.
B1202 Lennox no. P-8-11223; heat pump circuit; used
with T872R1040.
Y594R1243 Wiring differences (old=new):
V-VR=R, M=Y, Y=W2, F=G, R=O.
B1210 None
B1228 General Electric no. BAY28X137; isolated
G terminal.
Q674B1018
B1236 Carrier no. HH-93AZ079; RC-RH jumper;
LOCKOUT LED indicates compressor lockout
switch activated.
Q674B1034 RC-RH jumper; LED cannot be
provided in TRADELINE model.
B1244 Friedrich; heat mode changeover; used with
T872R1115.
T874C1018/
Q674B1034
Wiring differences (old=new): C=no
connection; RC-RH and W1-Y1
jumpers required.
B1251 Used with T872W1035 and C815A1043. Y594W1014
a
When replacing a T872 Thermostat and Q672 Subbase, always replace both the thermostat and subbase.

Table of Contents

Other manuals for Honeywell T874

Related product manuals