11 69-1676—1
Table 3. Heat Cycle Rate.
NOTE: The cooling cycle rate does not require adjustment and therefore cannot be changed.
Fahrenheit/Celsius Indication
Use DIP switch 3 to set the desired temperature indication. See Table 4.
Table 4. Temperature Indication.
STEP 9. MOUNT THE THERMOSTAT
Heating System Cycles Per Hour DIP Switch 1 DIP Switch 2
Steam, Gravity 1 On On
High Efficiency Warm Air (90%+ efficiency), Hot Water, Heat Pump 3 Off On
Gas or Oil Warm Air (factory setting) 6 Off Off
Electric Warm Air 9 On Off
In Floor Radiant Heat Check with manufacturer for recommended
cycle rate.
Fahrenheit/Celsius Display DIP Switch 3
Fahrenheit (factory setting) Off
Celsius On