PPaaggee 88
LLCCDD DDIISSPPLLAAYY FFEEAATTUURREESS -- AA ffuullllyy ggrraapphhiiccaall bbaacckk--lliitt
ddiissppllaayy wwhhiicchh aalllloowwss tthhee uusseerr tthhee bbeesstt ppoossssiibbllee
iinntteerrffaaccee wwiitthh tthhee pprrooggrraammmmee ttiimmeess aanndd
ffuunnccttiioonnss --
1 Current TIME OF DAY
2 Day of Week
3 Channel Heading
4 Current Channel programme
5 Next Channel switch time
LLEEDD IINNDDIICCAATTOORR -- IIlllluummiinnaatteedd bbuuttttoonnss ggiivvee aa
vviissuuaall ffeeeeddbbaacckk ttoo uusseerr ooppeerraattiioonnss,, aass wweellll aass
iinnddiiccaattiinngg tthhee ssttaattuuss ooff aa cchhaannnneell..
6 Channel ON indicator
EEAASSYY TTOO UUSSEE PPRROOGGRRAAMMMMEE AANNDD OOVVEERRRRIIDDEE BBUUTTTTOONNSS
-- AA mmeennuu ddrriivveenn ddiissppllaayy aanndd aa pprreesseett cclloocckk //
ccaalleennddeerr mmeeaannss tthhaatt pprrooggrraammmmiinngg iiss mmaaddee
ssiimmppllee.. AA oonnee ttoouucchh oovveerrrriiddee ffaacciilliittyy mmaakkeess
tteemmppoorraarryy cchhaannggeess ssiimmppllee ttoo uussee aanndd vviieeww..
7 ADVANCE and ENTER button
8 ADVANCE and PLUS button
9 BOOST and COPY button
10 BOOST and MINUS button
11 Programme Select buttons (Coloured Blue)
12 SET button (Coloured Green)
PPaaggee 11
Horstmann Controls Limited
Bristol
BS4 1UP
Email: sales@horstmann.co.uk
Website: www.horstmann.co.uk
II
NNTTRROODDUUCCTTIIOONN PPAAGGEE 11
PPRROODDUUCCTT OOVVEERRVVIIEEWW PPAAGGEE 11
DDIISSPPLLAAYY IINNFFOORRMMAATTIIOONN PPAAGGEE 22
DDEEFFAAUULLTT SSEETTTTIINNGGSS PPAAGGEE 22
AADDJJUUSSTTIINNGG TTIIMMEE AANNDD DDAATTEE PPAAGGEE 33
AADDJJUUSSTTIINNGG CCLLOOCCKK OOPPTTIIOONNSS PPAAGGEE 44
AADDJJUUSSTTIINNGG CCHHAANNNNEELL HHEEAADDIINNGGSS PPAAGGEE 44
SSEETTTTIINNGG TTHHEE PPRROOGGRRAAMMMMEE TTIIMMEESS PPAAGGEE 55
SSEETTTTIINNGG HHOOLLIIDDAAYY MMOODDEE PPAAGGEE 66
OOVVEERRRRIIDDEE FFAACCIILLIITTYY PPAAGGEE 66
BBOOOOSSTT FFUUNNCCTTIIOONN PPAAGGEE 77
AADDVVAANNCCEE FFUUNNCCTTIIOONN PPAAGGEE 77
RREESSEETT PPRROOCCEEDDUURREE PPAAGGEE 77
GGEENNEERRAALL IINNFFOORRMMAATTIIOONN PPAAGGEE 88
IINNDDEEXX
PPRROODDUUCCTT OOVVEERRVVIIEEWW --
DDEETTAAIILL SSHHOOWWNN WWIITTHH TTHHEE FFLLAAPP LLOOWWEERREEDD
GGEENNEERRAALL IINNFFOORRMMAATTIIOONN
BBAATTTTEERRYY
SSEERRVVIICCEE AANNDD RREEPPAAIIRR
This programmer is NOT user serviceable. Please do not dismantle the unit. In the unlikely
event of a fault developing please refer to the RESETTING THE PROGRAMMER section of this
user guide located on page 7. If this fails to resolve the problem please contact a local
heating engineer or a qualified electrician.
11
22
33
44
55
66
77
88
99
1100
1111
The programmer is fitted with a non-rechargeable, non-serviceable long life battery,
which will maintain the clock and programmed time settings with the mains supply
disconnected.
THIS RESERVE SHOULD BE SUFFICIENT TO COVER POWER INTERRUPTIONS DURING THE LIFE OF THE
UNIT.
During power interruptions the display will be blank.
CCHHAANNNNEELLPPLLUUSS HH3377XXLL SSEERRIIEESS 22
UUSSEERR IINNSSTTRRUUCCTTIIOONNSS
CChhaannnneellPPlluuss HH3377 XXLL SSeerriieess 22 TThhrreeee CChhaannnneell PPrrooggrraammmmeerr
Each independent channel can be set to provide up to three on and off
operations per day on a weekly schedule.
Series 2 ChannelPlus programmers directly replace earlier ChannelPlus
models.
1122
Question and Answer IconNeed help?

Do you have a question about the Horstmann channelplus H37 XL series 2 and is the answer not in the manual?

Horstmann channelplus H37 XL series 2 Specifications

General IconGeneral
TypeElectronic Programmer
ModelH37 XL Series 2
Power Supply230V AC 50Hz
Frequency50Hz
Temperature Range5°C to 30°C
DisplayLCD
MountingWall-mounted
InstallationProfessional installation recommended
CompatibilityCentral Heating Systems
Programming Capability7-day programming
Battery BackupYes
Channels3

Summary

General Information and Service

Battery Reserve

The programmer has a non-rechargeable, long-life battery to maintain clock and programmed time settings during mains power interruptions.

Service and Repair

The programmer is not user serviceable. Refer to resetting procedure or contact a qualified heating engineer or electrician for faults.

Product Overview and Features

LCD Display Features

A fully graphical back-lit display showing current time, day, channel heading, programme, and next switch time.

LED Indicator

Illuminated buttons provide visual feedback for user operations and indicate channel status.

Programme and Override Buttons

Menu-driven display and preset clock/calendar simplify programming. One-touch override for temporary changes.

Display Information and Settings

Display Information

The programmer has a graphical back-lit display divided into three sections for controlled channels, showing status and times.

Front Cover Instructions

Simple instructions require the front flap to be lowered. Replace flap for normal operation.

Default Settings

The programmer has factory presets for Time/Date, Clock Options (24hr/AM/PM), and Headings (Heating/Water, Zone, Channel).

Boost Function Override

Allows temporary override of a channel for 1 or 2 hours, extending current periods or turning off.

Advance Function

Brings forward the next ON or OFF operation for a channel, indicated by the illuminated button.

Reset Procedure

Procedure to restore factory settings if display freezes or scrambles. Resets time to 1st Jan 2005.

Advanced Programming Features

Setting Holiday Mode

Suspends program function for a set period, indicated by a smiley face. Operates mid-day to mid-day.

Programme Override Facilities

Allows overriding programmed times to Auto, All day, On, or Off for each channel, unaffected by schedule.

Adjusting Time and Date

Procedure to adjust the current time and date if modifications are required. Affects Holiday and Boost/Advance.

Configuration Options

Adjusting Clock Options

Allows changing the time display from 24-hour format to AM/PM format.

Adjusting Channel Headings

Allows changing the channel heading from 'Heating/Water' to 'Zone' or 'Channels'.

Setting Programme Times

Procedure to change pre-set ON/OFF times for channels, with default settings for Mon-Fri and Sat-Sun.