The following chart shows all of the adjustable parameters. Refer to steps 7 and 8 on page H603.1 to make any necessary changes
H603.2
oF (no)
OP (power fail OPen)
oF (no)
oF (no) (Version 3.01 & up only)
oF (no) (Version 3.01 & up only)
oF (use standard speeds)
oF (use standard speeds)
oF (use standard accelaration)
oF (standard switches in use)
oF (on if Horton lock is present)
oF (fail-secure/on if fail-safe lock found)
oF (monitored lock)
oF (standard lock)
oF (Do not turn on - see Q3-4)
oF (Lock only when closed)
oF (Version 3.03 & up only)
oF (Version 3.02 & up only)
Note: a double dash (--) is a reversed parameter that is not implemented
10
12
4
4
3
3
1 sec
1 sec
3 sec
75% of stroke
8"
(as determined by learn cycle)
oF (no)
oF (no)
on (yes)
FACTORY PRESET VALUE
SECTION 2: OTHER DISPLAY CODES
(Version 3 software)
Lock Open also
reverse on encoder Pulses
The following initialization, error, and diagnostic codes may also
be displayed at various times by Bersion 3 software:
Control is braking door.
Setup data stored.
Door is closed and idle (waiting for actuate signal).
Door is latched in full open position.
Partial open check (when partial opening is activated).
No automatic lock found.
Interlocking active - contact on CN2, pin 13 inhibiting
door open.
No lock found (or lock does not have monitor switch).
Fail secure automatic lock (with monitor switch) found.
Fail safe automatic lock (with monitor sitch) found.
First run - finding fully closed position.
First run - finding fully open position.
Jam Sensing
Open Check
Close Speed
Close Check
Open cUshion
Close cUshion
delay time 1 (full)
delay time 2 (partial)
delay time 3 (reverser)
open Check Point
Partial Open position
total Stroke
cycle test
AutoSeal
Stop OK on first run
Lock present
Close braking
brake on recycles
use SLow speeds
use turbocharge speeds
reduced Accelaration
3-button station present
PARAMETERCODE
Open Speed
Safety nosings
Fail-SAfe lock
Unmonitored Lock
Power Fail
Heavy-duty door/motor
Horton C9910 Lock
bi-stable Lock
oF/on
oF/on
Jam sensed - door not moving at beginning of open or
close cycle.
Pedestrian (actuating or safety device) stopping "learn"
cycle.
No close monitor microswitch found when expected.
Unlock failure of (monitored) automatic lock.
Lock failure of (monitored) automatic lock.
Encoder failure.
Loss of pulses from encoder.
Encoder phasing wrong.
Encoder test starting.
Rotating lines during encoder test.
Stroke determination failure (measured stroke outside
limits).
Data storage failure.
Battery failure (when optional battery pack is installed).
oF/on
12-199"
oF/on
oF/on
oF/on
oF/on
oF/on
oF/on
oF/on
oF/on
oF/on
oF/on
oF/on
oF/on
oF/on
ADJUSTS
0-15
0-15
0-15
0-15
0-15
0-15
OP/CL
oF/on
1-199
1-199
1-199
50-90% tS
8"-tS
oF/on