x Page 11 x Page 11 Pre-Delivery Instructions
INSTALLATION NOTE: After the spa has been installed, your electrician can connect the conduit from the subpanel
to the spa’s control box and then complete the wiring connections in the control box. NOTE: Complete step-by-step
Installation and Wiring Instructions for all models are included in the Owner’s Manual.
WARNING: Removing or bypassing the GFCI breakers in the subpanel at any time will result in an unsafe spa and
will void the warranty.
SPA SPECIFICATIONS
CONTRACTOR SUGGESTIONS
Electrician
Name: ____________________________________________________________________________
Telephone: ____________________________________________________________________________
Name: ____________________________________________________________________________
Telephone: ____________________________________________________________________________
General
Name: ____________________________________________________________________________
Telephone: ____________________________________________________________________________
Name: ____________________________________________________________________________
Telephone: ____________________________________________________________________________
CONTROL BOX
PANEL
ELECTRICAL
MAIN SERVICE
LESS THAN 100 FT.
#8 AWG RED, L2
#8 AWG BLACK, L1
#8 AWG GREEN, GROUND
#8 AWG WHITE, NEUTRAL
50A
WITHIN SIGHT OF THE SPA
THE SUB-PANEL MUST BE
MORE THAN 5 FEET
DO NOT EXCEED 50 FEET
WITH GFCI
BREAKERS
50A
SUB-PANEL
L2
GRD
L2, HOT, #8 AWG RED
L1, HOT, #8 AWG BLACK
GROUND, #8 AWG GREEN*
N, NEUTRAL, #8 AWG WHITE
L1L2
N
PERMANENTLY CONNECTED
230 VAC, 50A, 60Hz, MODELS
230VAC, 50 Amp
2-POLE
CIRCUIT BREAKER
(NON GFCI)
N
L1
GND
ILLUSTRATION
SEE WIRING
230 VAC PERMANENTLY CONNECTED SPA
L1L2
N
CONVERTED 230VAC SPA MODELS
JUMPERS REQUIRED
NO POWER
JP1
JP2
JP6
JP3
JP4
JP5
JP8
JP7