Engineering Specifications – SR Models
Model No.
Cabinet Dimensions
D x H* x L
Compressor
HP
Electrical Voltage
Max. Amps
Power Cord
Plug (NEMA)
SR22 35 x 83 x 26 1/2 1/4 115/60Hz/1PH 6.8 5-15P
SR48 35 x 83 x 52 1/4 1/3 115/60Hz/1PH 9.6 5-15P
SR75 35 x 83 x 78 1/2 115/60Hz/1PH 12.1 5-20P
* - Includes 5" Casters
or
** = Top mounts does not includes 6" Legs
These cabinets are designed to operate in an air
conditioned location ONLY.
Temperature not to exceed 75