13–18 Programming Techniques
File name 32sii-Manual-E-0424
Printed Date : 2003/4/24 Size : 17.7 x 25.2 cm
.
.
.
%!
variable
A DSE instruction is like a FOR–NEXT loop with a negative increment.
After pressing a shifted key for ISG or DSE (
z
k
or
{
m
), you
will be prompted for a variable that will contain the loop–control number
(described below).
The Loop–Control Number
The specified variable should contain a loop–control number ±ccccccc.fffii,
where:
±ccccccc is the current counter value (1 to 12 digits). This value changes
with loop execution.
fff is the final counter value (must be three digits). This value does not
change as the loop runs.
ii is the interval for incrementing and decrementing (must be two digits or
unspecified). This value does not change. An unspecified value for ii is
assumed to be 01 (increment/decrement by 1).
Given the loop–control number ccccccc.fffii, DSE decrements ccccccc to
ccccccc — ii, compares the new ccccccc with fff, and makes program
execution skip the next program line if this ccccccc
fff.
Given the loop–control number ccccccc.fffii, ISG increments ccccccc to
ccccccc + ii, compares the new cccccccc with fff, and makes program
execution skip the next program line if this ccccccc
>
fff.