Loading...
User Memory and the Stack B–5
File name 32sii-Manual-E-0424
Printed Date : 2003/4/24 Size : 17.7 x 25.2 cm
All functions except those in the following two lists will enable stack lift.
Disabling Operations
The four operations ENTER,
Σ
+,
Σ
–, and CLx disable stack lift. A number
keyed in after one of these disabling operations writes over the number
currently in the X–register. The Y–, Z– and T–registers remain unchanged.
In addition, when
and
@
act like CLx, they also disable stack lift.
The INPUT function disables stack lift as it halts a program for prompting (so
any number you then enter writes over the X–register), but it enables stack lift
when the program resumes.
Neutral Operations
The following operations do not affect the status of stack lift:
DEG, RAD,
GRAD
FIX, SCI,
ENG, ALL
DEC, HEX, OCT,
BIN
CLVARS
PSE SHOW RADIX .
RADIX ,
CL
Σ
f
and STOP
z
and
z
* and
a
*
X
{
#
}**
EQN
X
{

}**
FDISP
U
Errors
GTO
label nn
d
and
program entry
Switching
binary windows
Digit entry
Except when used like CLx.

Including all operations performed while the catalog is displayed
except {
#
}
and {

}
W
, which enable stack lift.

Table of Contents