7
Model
3336A/B/C
Up
to
15
instruments
(including
the
controller)
may
be
connected
in
an
HP-IB
system.
The
HP-IB
cables
have
identical
stacking
connectors
on
both
ends
so
that
several
cables
can
be
connected
to
a
single
source.
As
a
practical
matter,
avoid
stacking
more
than
three
or
four
cables
on
any
one
connector.
If
the
stack
gets
too
large,
the
force
on
the
stack
can
produce
enough
leverage
to
damage
the
connector
mounting.
Be
sure
that
the
connector
screws
are
tightened
firmly
in
place
to
keep
it
from
working
loose
during
use,
and
be
sure
to
observe
the
CAUTION
of
Figure
2-2.
ST0-
8
4090
The
3336A
contains
metric
threaded
HP-I8
cable
mounting
studs
as
opposed
to
English
threads.
Metric
threaded
-hp-
10833
A,
8B,
C,
or
D
HP-iB
cable
lockscrews
must
be
used
to
secure
the
cable
to
the
instrument.
Identification
of
the
two
types
of
mounting
studs
and
lockscrews
is
made
by
their
color.
English
threaded
fasteners
are
colored
silver
and
metric
threaded
fasteners
are
colored
black.
DO
NOT
mate
silver
and
black
fasteners
to
each
other
or
the
threads
of
either
or
both
will
be
destroyed.
Metric
threaded
HP-/B
cable
hardware
illustrations
and
part
numbers
follow.
0101
D102
DI03
D104
DIOS
DIO6
D107
bt08
EOI
REN
DAV
NRFO
LOCKSCREW
LONG
MOUNTING
STUD
SHORT
MOUNTING
STUD
NDAC
1390-0360
0380-0643
0380-0644
IFC
SRQ
ATN
SHIELD—CHASSIS
GROUND
P/O
TWISTED
PAIR
WITH
PIN
6
P/O
TWISTED
PAIR
WITH
PIN
7
ee
P/O
TWISTED
PAIR
WITH
PIN
8
INTERNALLY
P/O
TWISTED
PAIR
WITH
PIN
9
CONNECTED
P/O
TWISTED
PAIR
WITH
PIN
10
TO
AN
P/O
TWISTED
PAIR
WITH
PIN
11
ISOLATED
ISOLATED
DIGITAL
GROUND
GROUND:
Figure
2-2.
HP-IB
Connector.
2-14.
Cable
Length
Restrictions.
System
components
can
be
interconnected
in
virtually
any
configuration.
However,
to
achieve
reliable
system
performance,
proper
voltage
levels
and
timing
relationships
must
be
maintained.
If
the
system
cable
is
too
long,
the
lines
cannot
be
driven
properly
and
the
system
will
fail
to
perform.
The
maximum
length
of
cable
that
can
be
used
to
connect
a
group
of
instruments
must
not
exceed
2
meters
(6.5
ft.)
times
the
number
of
instruments
to
be
connected,
or
20
meters
(65.6
ft.),
whichever
is
less.
2-15.
3336
Listen/Talk
Address.
2-16.
The
Model
3336
is
normally
shipped
from
the
factory
with
the
Device
address
of
4,
(talk
address
D,
listen
address
$).
The
address
switches
are
located
on
the
rear
panel.
The
binary
weighted
HP-IB
address
switches
1
thru
5
set
the
Device
address
and
consequently
the
Talk
and
Listen
address.
All
the
possible
Device,
Listen
and
Talk
addresses
and
the
HP-IB
address
switch
positions
are
shown
in
Table
2-1.
Switch
6,
marked
‘‘Listen
Only’’,
disables
the
instruments
talk
capability.
This
is
normally
left
in
the
position
(talk
enabled).
Switch
7
is
not
used.
The
instrument
will
display
its
Device
address
for
1
second
after
pressing
the
Blue
Shift
key
and
then
the
LOCAL
key.
Installation
2-3