EasyManua.ls Logo

HP 3455A - Page 31

HP 3455A
249 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Model 34S5A
Section
III
Tables^. HP-IB Program
Codes.
Progratrt
Control Code
DC Volti
FI
AC
Volts F2
FUNCTION Fast
AC
Volts F3
2 Wire kR
F4
4
Wire
kR F5
Test F6
.1 R1
1
H2
10 R3
RANGE 100 R4
1 K R6
10 K R6
AUTO
H7
Internal
T1
TRIGGER
External
T2
Hold/Manual
T3
Scale Ml
MATH Error M2
Oft M3
ENTER
Y
Z
EY
EZ
STORE
Y
2
SY
SZ
AUTO CAL
Off
On
Al
HIGH
Off
HO
RESOLUTION On HI
DATA
Off
00
READY RQS On Dl
BINARY
PROGRAM
B
3-58.
The program code for single
control features
which can only be programmed on
or
off
(AUTO CAL
and
HIGH
RESOLUTION) consist of the letter
underlined in the control
heading and the number
“0”
for off or the number **l” for on. This also applies
to
the DATA READY
Request feature which
is
Bus pro-
grammable only.
Example:
0
=
off
1
=
on
Program Code
(ofO
(on)
3-59.
Program codes for the ENTER
and STORE
features consist of
the letter underlined in the control
control
code
(underlined)
AUTO
CAC
PATA
CAOr
BOS
94H
A0
Al
1X9
Dl
heading
and
the
underlined
letter of the particular con-
trol.
Example:
control group code
(underlined)
CNTCN
control codes
(underlined)
^ad«-47«4
program
code
EY EZ SY SZ
3-60.
The
program
code of the BINARY PROGRAM
feature consists of only the underlined character in the
control heading (B).
3-81.
Data Maataget.
3-62.
The major portion of communications transmit-
ted
over
the Bus is accomplished by data messages. Data
messages are used by the controller to program the
Model 34SSA and are used by the 34SSA to transmit
measurement
data.
These functions are explained
in
the
following
paragraphs.
3-83.
Programming. The 345SA is programmed by means
of data messages sent over the Bus from the controller.
These messages are composed of
two
parts
the ad-
dress command and the program information. The ad-
dress command contains the "talk” and “listen” ad-
dresses of the
devices involved;
in this case, the talk ad-
dress of the controller and the listen address of the
34S5A. The
program information contains the codes of
the 345SA controls to be programmed. Syntax of the ad-
dress command portion of
the data message
is
depen-
dent upon the
controller
being used. For
the proper syn-
tax refer to the controller manual.
Syntax for
the
pro-
gram information portion consists
of the program codes
listed in Table
3-4.
Example program data messages:
Address
Command
3455A Program
Infonnation
CMD-’Ub". -FI R3
M iiJ
M3
13
output
to
J
the bus
unlisicn
command
controller
_
“talk" address
3455A
“listen" address
I
HOLD/
••MANUAL
TRIGGER
-MATH off
HIGH
RESOLUTION
on
AUTO CAL
off
10 V RANGE
DC Volts FUNCTION
Program data message using the 9830A Calculator.
3-9

Related product manuals