NIC agents 132
Log Severity: Warning (2)
Log Message: The NIC Agent service could not load the module “%1”. The data contain the error
code.
Event identifier: cpqnimsg.dll - 288 (Hex)0x84350120 (Service Event)
Log Severity: Warning (2)
Log Message: The NIC Agent service could get the control function for module “%1”. The data
contain the error code.
Event identifier: cpqnimsg.dll - 290 (Hex)0x84350122 (Service Event)
Log Severity: Warning (2)
Log Message: The NIC Agent service could not start agent “%1”. The data contain the error code.
Event identifier: cpqnimsg.dll - 291 (Hex)0x84350123 (Service Event)
Log Severity: Warning (2)
Log Message: The NIC Agent service detected an invalid state for agent *”%1”. The data contain the
state.
Event identifier: cpqnimsg.dll - 292 (Hex)0x84350124 (Service Event)
Log Severity: Warning (2)
Log Message: The NIC Agent service could not stop agent “%1”. The data contain the error code.
Event identifier: cpqnimsg.dll - 293 (Hex)0x84350125 (Service Event)
Log Severity: Warning (2)
Log Message: The NIC Agent service could not terminate agent “%1”. The data contain the error
code.
Event identifier: cpqnimsg.dll - 294 (Hex)0x84350126 (Service Event)
Log Severity: Warning (2)
Log Message: The NIC Agent service could not unload the module “%1”. The data contain the error
code.
Event identifier: cpqnimsg.dll - 296 (Hex)0xc4350128 (Service Event)
Log Severity: Error (3)
Log Message: A driver for a NIC failed to open. This error can be caused by an improperly installed
adapter. Removing and reinstalling all adapters may correct the problem. The NIC Agent service will
not respond to any management requests.
Event identifier: cpqnimsg.dll - 297 (Hex)0x84350129 (Service Event)
Log Severity: Warning (2)
Log Message: An attempt to log an event to the IML failed. The IML log may be full. Clearing the IML
log may correct this problem.
Event identifier: cpqnimsg.dll - 298 (Hex)0xc435012a (Service Event)
Log Severity: Error (3)
Log Message: A fatal error occurred during Virus Throttle WMI event processing. Virus Throttle related
traps will not be sent.

Other manuals for HP 4X - DDR InfiniBand Mezzanine HCA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 4X - DDR InfiniBand Mezzanine HCA and is the answer not in the manual?

HP 4X - DDR InfiniBand Mezzanine HCA Specifications

General IconGeneral
BrandHP
Model4X - DDR InfiniBand Mezzanine HCA
CategoryServer
LanguageEnglish

Related product manuals