OPERATOR'S
SELF-CHECK
PROCEDURE
3-12.
This
section,
beginning
with
paragraph
3-225,
includes
checks
that
allow
the
operator
to
make
a
quick
evaluation
of
the
counter’s
operation.
These
checks
will
fundamentally
verify
the
following:
Keyboard
Display
and
Annunciators
Memory;
RAM
and
ROM
HP-IB
3-13,
GENERAL
OPERATION
INFORMATION
BEFORE
THE
INSTRUMENT
IS
SWITCHED
ON,
ALL
PROTECTIVE
EARTH
TERMINALS,
EXTENSION
CORDS,
AUTOTRANS¬
FORMERS
AND
DEVICES
CONNECTED
TO
IT
SHOULD
BE
CONNECTED
TO
A
PROTECTIVE
EARTH
GROUNDED
SOCKET,
ANY
INTERRUPTION
OF
THE
PROTECTIVE
EARTH
GROUND¬
ING
WILL
CAUSE
A
POTENTIAL
SHOCK
HAZARD
THAT
COULD
RESULT
IN
PERSONAL
INJURY.
ONLY
THE
250V
FUSES
WITH
THE
REQUIRED
RATED
CURRENT
AND
SPECIFIED
TYPE
SHOULD
BE
USED,
DO
NOT
USE
RE¬
PAIRED
FUSES
OR
SHORT
CIRCUITED
FUSEHOLDERS.
TO
DO
SO
COULD
CAUSE
A
SHOCK
OR
FIRE
HAZARD.
3-14.
Power-Up/Self-Check
3-15.
When
the
counter
is
turned
on,
an
internal
check
is
made
of
several
major
components
in
its
circuitry.
During
this
cycle,
all
front
panel
segments
and
indicators
will
light
momentarily,
followed
by
the
momentary
display
of
the
instrument’s
decimal
HP-IB
address
(e.g„
HP-IB
Addr
28).
3-16.
After
the
power-up
sequence,
the
counter
will
initialize
itself.
Ail
math
and
statistics
will
be
off,
the
function
will
be
Frequency
A,
and
the
gate
and
cycle
modes
will
be
in
Norm.
All
of
the
input
controls
will
be
set
according
to
their
switch
positions.
3-17.
Any
failures
during
the
power-up
cycle
will
disable
the
counter
and
produce
a
display
of
numbered
error
or
fail
messages.
Within
the
5335A,
fail
messages
generally
indicate
a
hard¬
ware
failure,
and
error
messages
indicate
the
user
has
attempted
an
improper
operation.
Refer
to
Error
Messages,
paragraph
3-229.
3-18.
Display
3-19.
The
number
to
be
displayed
is
formatted
into
engineering
notation
with
the
digits
grouped
into
threes
for
convenient
reading
and
an
exponent
with
a
range
of
±18.
When
dis-
3-2
Model
5335A