EL-MF877-00 Page 5
Template Revision B
Figure 6 Treatments to fan module 9
1. Remove the nine fans 9-2 from fan frame 9-1;
2. Unscrew the screws on PCB 9-3, and then remove PCB 9-3;
3. Remove all of the inner cables;
4. Unscrew the screws on handle 9-4, and then remove handle 9-4;
5. Remove film 9-5 from fan frame 9-1;
6. Remove shielding finger 9-6 from fan frame 9-1.
3.2 Material of the facility built
Facility Components Material Weight
(g)
Weight
percentage
Selective treatment for
materials and components
Details
1 Fe
23254 47.94%
Fe recycling
2 Fe
932 1.92%
Fe recycling
3 ABS
58 0.12%
Pla recycling
4
4-1 Fe
1566 3.23%
Fe recycling
4-2
Complex PWB 528 1.09% The surface of PCB is
greater than 10
square centimeters
4-3
Fe
92.7
0.19%
Fe recycling
4-4
Complex PWB 1000 2.06% The surface of PCB is
greater than 10
square centimeters
5
5-1 Fe
1487 3.07%
Fe recycling
5-2
Complex PWB 1000 2.06% The surface of PCB is
greater than 10
square centimeters
6
6-1
Fe 303*6 3.75%
Fe recycling
7
Complex
PWB+Fe
8021 16.54% 1. Containing
brominated flame
retardants ;
2. The surface of
PCB is greater
than 10 square
centimeters;
3. Electrolyte
Fe recycling