EasyManuals Logo

HP 8642A Operation And Calibration Manual

HP 8642A
314 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #226 background imageLoading...
Page #226 background image
Operation
Model
8642A/B
Operating
Messages
(cont'd)
AMPTD
SF
AN
30DB
MAX
.E63
4063
An
amplitude
span
of
30
dB
is
the
maximum
possible span.
Either
select
an
amplitude
sweep
setting
within
the
30
dB
span
limitation
or
turn
off
the
other
amplitude
sweep
start
or
stop
value
(HP-
IB:
AAOF
or
ABOF).
AP.SWP
LIMITS
MIN
TIME
.E64
4064
The
minimum
sweep
time
possible
for
amplitude
sweep
is
20
ms.
Either
select
another
sweep
time
or
turn
off
amplitude
sweep
(HP-
IB:
AAOF
ABOF).
AP.SWP
PREVENTS
SP9
.E65
4065
Special
Function
9
(Attenuator
Range
Hold)
is
not
possible
during
amplitude
sweep.
Turn
off
amplitude
sweep (HP-IB:
AAOF
ABOF)
and
set
amplitude
(HP-IB: AP)
before
selecting
attenuator
range
hold
(HP-IB: SP9).
SP9
PREVENTS
AP.SWP
.E66
4066
Amplitude
sweep is
not
possible
when
Special
Function
9
(Attenuator
Range
Hold) IS selected. Select
Attenuator
Range
Hold
Off
(Special
Function
209)
before
selecting
amplitude
sweep.
AM
PREVENTS
AP.SWP
.E68
4068
Amplitude
sweep
is
not
possible
when
AM
IS selected.
Turn
off
AM
(HP-IB: AMOF)
before
selecting
amplitude
sweep.
AP.SWP
PREVENTS
AMPTD
.E69
4069
Output
amplitude
cannot
be set
during
amplitude
sweep.
Turn
off
amplitude
sweep (HP-IB:
AAOF
ABOF)
before
selecting
the
output
amplitude
.
AMPTD
SWP
PREVENTS
AM
.
E70
4070
AM
is
not
possible
during
an
amplitude
sweep.
Turn
off
amplitude
sweep (HP-IB:
AAOF
ABOF)
before
selecting
AM.
AP.SWP
PREVENTS
AP.OFF
.E71
4071
Output
amplitude
cannot
be
turned
off
during
amplitude
sweep.
Turn
off
the
amplitude
sweep
(HP-IB:
AAOF
ABOF)
before
turning
off
the
output
amplitude
.
AP.SWP
PREVENTS
PULSE
.
E72
4072
Pulse
modulation
is
not
possible
during
an
amplitude
sweep.
Turn
off
the
amplitude
sweep (HP-IB:
AAOF
ABOF)
before
selecting
pulse
modulation
.
AP.SWP
PREVENTS
SP4
.
E73
4073
Special
Function
4 (ALC
OFF)
is
not
possible
during
amplitude
sweep.
Turn
off
amplitude
sweep
(HP -IB:
AAOF
ABOF)
before
selecting
ALC
OFF
(HP-IB
SP4).
SP4
PREVENTS
AP.SWP
.E74
4074
Amplitude
sweep is
not
possible
when
Special
Function
4 (ALC
OFF)
is
selected. Select
Disable
ALe
OFF
(Special
Function
204)
before
selecting
amplitude
sweep .
SP9
LIMITS
MIN
AMPTD
.
E75
4075
Special
Function
9
(Attenuator
Range
Hold)
limits
the
mInImUm
amplitude
that
can
be selected. To
resol ve
this
problem,
ei
ther
1)
select
Attcnuator
Range
Hold
Off
(Special
Function
209),
or
2)
select
an
amplitude
within
the
held
amplitude
range
selected,
(refer
to
Table
3-1
5,
page
3
-7
5,
or
Figure
3
--
9,
page 3
-7
6),
or
3-190
rev.20MAR85

Table of Contents

Other manuals for HP 8642A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 8642A and is the answer not in the manual?

HP 8642A Specifications

General IconGeneral
BrandHP
Model8642A
CategoryInverter
LanguageEnglish

Related product manuals