Model
864
2A/B
PROCEDURE:
rev.22JAN87
1.
Performance Tests
PERFORMANCE
TESTS
Setup
Connect the equipment
as
shown
in
Figure
4-4.
Preset the
instruments. On
the
measuring receiver, enable
the
300
Hz HP
Filter
and
the
3 kHz LP Filter.
2.
Residual AM
Put
the
measuring receiver
in
AM mode using
the
rms detector. Set
the
HP
8642
to
the
levels
and
frequencies in
the
following table
and
verify
that
the
measuring receiver reading
is
less
than
the
specified
maximum.
8642
8642
Results
AMPTD
FREQ
(dBm)
Actual Max
18 1 MHz
0.010%
18 1 GHz
0.010%
16
1.3 GHZl
0.010%
5
1 MHz 0.010%
5
1 GHz 0.010%
5
1.3 GHZl
0.010%
1 86428 only.
3.
Residual FM
Put
the
measuring receiver in FM mode
and
leave
the
rms detector
ena bled. Set
the
HP 8642
to
the levels
and
frequencies in
the
following table
and
verify
that
the
measuring receiver reading
is
less
than
the
specified maximum.
8642
8642
Results (kHz)
AMPTD
FREQ
(dBm)
Actual
Max
10 250 MHz
0.0010
10 0.5 GHz 0.0012
10 1 GHz 0.0020
10 1.3 GHz
0.0050