EasyManua.ls Logo

HP 8920A - Page 128

HP 8920A
322 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AM Transmitters
126
Measurement Procedure:
1. Connect the Transmitter as shown.
CAUTION: The RF present at the Test Set RF IN/OUT connector must not exceed 60W
continuous (or 100 Watts for 10 sec/minute).
On the Test Set:
2. Press the PRESET key.
3. Press the TX key.
Using the knob and data keys:
4. Set AF Anl In to AM Demod.
5. Set Filter 1 to 300 Hz HPF.
6. Set Filter 2 to 3 kHz LPF.
On the Radio:
7. Key the Transmitter and keep keyed until the remaining steps are
completed
On the Test Set using the knob and data entry keys:
8. Set AFGen1 Lvl so that displayed AM depth is 30%.
On the Test Set Microphone Sensitivity is shown as AFGen1 Lvl.
Special Test Considerations
See "Incidental Audio" on page 46.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Other manuals for HP 8920A

Related product manuals