HP C30 - TAG 045: Charge Corona Circuit Shorted

HP C30
487 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TAG 045: Charge Corona Circuit Shorted
3-60 Troubleshooting Analysis Guide (TAGs) June 1999
TAG 045: Charge Corona Circuit Shorted
Error Code: 045
Possible Defects: Charge corona
High voltage unit
Charge corona terminal assembly
Connectors or wiring
PCL board
1
Turn the printer off and unplug the power cord.
Verify that J/P23, J/P41, J/P85, P124, P143, and the high voltage unit charge corona lead are
connected properly.
Clean the charge corona contacts.
Power-on-reset the printer.
Run test prints.
Is error code 045 displayed?
No: Loose connectors or dirty contacts were at fault. Turn to TAG 002: Check & Problem
Resolution.
Yes: Continue.
2
Has the charge corona been replaced recently?
No: Continue.
Yes: Go to #4 in this TAG.
3
Replace the charge corona and photoconductor unit.
Run test prints.
Is error code 045 still displayed?
No: The charge corona was at fault. Turn to TAG 002: Check & Problem Resolution.
Yes: Reinstall the original charge corona and photoconductor unit, then continue.
4
Turn the printer off and unplug the power cord.
Disconnect the charge corona lead from the high voltage unit.
Check for continuity the charge corona terminal assembly’s lower contact to the lead removed
from the high voltage unit.
Is there continuity?
No: Repair or replace the high voltage lead or the charge corona terminal block, then turn to
TAG 002: Check & Problem Resolution.
Yes: Continue.