TAG 097: +12 Vdc Power Shorted or Sensing Problem
3-88 Troubleshooting Analysis Guide (TAGs) June 1999
47
Turn off the printer and unplug the power cord.
• Disconnect J/P309.
• Check for continuity to ground:
P309-4 to P319-1, and
P309-3 to P318-1
Is there continuity at either?
No: Replace duplex control board #1, then turn to TAG 002: Check & Problem Resolution.
Yes: Repair or replace the connectors or wiring from:
P309-4 to P319-1, or
P309-3 to P318-1;