Every-Call Cleaning Procedure
General Printer Maintenance 9-7
Clean the Developer Unit
Inspect the unit for damage or contamination; repair or replace as necessary.
Clean any excess toner from the developer unit with a soft cloth.
Clean the toner patch sensor lens with a soft cloth, making sure no lint remains on the
lens.
Vacuum the felt areas around the magnetic roller, being careful not to vacuum toner
from the magnetic roller.
Reinstall the developer unit.
Clean the Cleaner Unit/Main Charger
Inspect the unit for damage or contamination; repair or replace as necessary.
Remove the charge corona from the cleaner unit.
Clean the grid with the cleaner brush.
Remove the grid to expose the corona wire.
Clean the corona wire with a cotton swab.
Reinstall the grid.
Clean any excess toner from the cleaner unit with a soft cloth.
Reinstall the charge corona in the cleaner unit.
Reinstall the cleaner unit.
Clean the Photoconductor Unit Area
Clean the photoconductor seam sensor inside the printer.
Remove the photoconductor from its protective packaging.
Inspect the photoconductor for damage or contamination; repair or replace as neces-
sary.
Reinstall the photoconductor unit.
Clean the Transfer Corona
Remove the transfer corona.
Clean the transfer corona housing with a soft cloth.
Clean the transfer corona wire with a cotton swab.
Reinstall the transfer corona.
Run Test Prints
Run test prints to verify print quality.