Tray/bin manual sensor test
The table in this section lists the sensors and switches available in the Tray/Bin Manual Sensor Test.
Use the tray/bin manual sensor test
The Tray/Bin Manual Sensor Test screen shows the sensor number, sensor name, sensor state (active or
inactive), and the number of times the sensor has been toggled (activated).
1. From the Home screen on the product control panel, scroll to and touch the Administration button.
2. Open the following menus:
●
Troubleshooting
●
Diagnostic Tests
●
Tray/Bin Manual Sensor Test
3. Touch the sensor number and name on the Tray/Bin Manual Sensor Test screen to display a sensor
location graphic on the control-panel display.
4. Activate the desired sensor, and then check the control-panel display to verify the sensor state (active
or inactive).
●
The State virtual LED next to the sensor number and sensor name illuminates green when the
sensor is active.
●
The Toggle virtual LED next to the sensor number and sensor name illuminates green after the
sensor is activated and increments by one each time the sensor is interrupted (activated or
deactivated).
For example, opening Tray 2 increments the SW7,8 Tray 2 Paper Size Toggle item count two times
—once when the tray is opened, and once when the tray is closed.
5. Touch the Reset Sensors button to reset the Toggle count item.
-or-
Touch the Cancel button to exit the Manual Sensor Test screen and return to the Diagnostic Tests menu.
Table 2-14 Tray/bin manual sensors
Sensor or switch name Replacement part number Descriptions
SR2 Tray 3 paper surface sensor 2
NOTE: 1x500-sheet feeders, 2x500-
sheet feeder, and 2,500-sheet HCI.
RM2-0341-000CN Paper pickup assembly
SR3 Tray 3 paper presence sensor
NOTE: 1x500-sheet feeders, 2x500-
sheet feeder, and 2,500-sheet HCI.
RM2-0341-000CN Paper pickup assembly
SR4 Tray 3 feed sensor
NOTE: 1x500-sheet feeders, 2x500-
sheet feeder, and 2,500-sheet HCI.
RM2-0341-000CN Paper pickup assembly
152 Chapter 2 Solve problems ENWW