N Tray 2 closed sensor
1. Remove Tray 2.
NOTE: The Tray 2 closed sensor flag is on the back of Tray 2. Inspect the flag to verify that it is
aligned correctly. If it is bent upward, it might miss the sensor when installed.
Figure 7-21 Test the Tray 2 closed sensor (1 of 2)
2. Insert a piece of paper in the Tray 2 closed sensor.
Figure 7-22 Test the Tray 2 closed sensor (2 of 2)
3. Check the control-panel display for sensor response.
4. If there is no response, replace the lifter-drive assembly. See
Lifter-drive assembly on page 254.
O Tray 2 stack-surface sensor
1. Remove Tray 2.
336 Chapter 7 Solve problems ENWW