Security Locks Supported
Hood Cover Security Loop (standard but
Lock not included)
Hood Cover Security Loop (standard but
Lock not included)
Interfaces
I/O Chip
SMSC LPC47B397 Super I/O SMSC LPC47B397 Super I/O
Serial Port / UART Type
One Serial Port One Serial Port
Parallel Port
One Parallel Port One Parallel Port
USB
8 USB 2.0 ports (6 rear/2 front) 8 USB 2.0 ports (6 rear/2 front)
Infrared Port
No No
Network
RJ-45 RJ-45
Keyboard
Yes (PS2 and USB) Yes (PS2 and USB)
Mouse
Yes (PS2 and USB) Yes (PS2 and USB)
Multibay
No No
Video (VGA/DVI-D)
Yes/Yes Yes/Yes
Audio
Yes Yes
Unit Environment and
Operating Conditions
Microtower
Slim Tower
General Unit Operating Guidelines
Keep the computer away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that unit is
operated within the specified operating range.
Leave a 10.2 cm (4 in) clearance on all vented sides of the computer to permit the required airflow.
Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that they are subject to each other's re-
circulated or preheated air.
Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint, dust and other foreign
matter can block the vents and limit the airflow.
If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must be provided on the enclosure,
and the same operating guidelines listed above will still apply.
Power Supply
Power Supply
250-watt ATX power supply - PFC
115v/230v line switch
200-watt ATX power supply - PFC
115v/230v line switch
Full Ranging Input (No Line Select Switch)
No No
Active Power Factor Correction (APFC) (Input
Current is nearly 1/2 a non-APFC PS)
No No
Passive Power Factor Correction (PFC)
Yes (with line switch set to 230V - No PFC in
115V line switch position)
Yes (with line switch set to 230V - No PFC in
115V line switch position)
Operating Voltage Range
90 to 132VAC, or 180 to 264VAC 90 to 132VAC, or 180 to 264VAC
Rated Voltage Range
100 to 127VAC, or 200 to 240VAC 100 to 127VAC, or 200 to 240VAC
Rated Line Frequency
50-60 Hz 50-60 Hz
Operating Line Frequency Range
47-63 Hz 47-63 Hz
Rated Input Current
5A @ 100VAC/2.5A @ 200VAC
6A @ 115VAC/23.0A @ 230VAC
Maximum Rated Power
250 watt 200 watt
QuickSpecs
HP dx5150 Business PC
Standard Features
DA - 12105 North America — Version 26 — July 10, 2007